Multiresidue liquid chromatography tandem mass spectrometry determination of 52 non gas chromatography-amenable pesticides and metabolites in different food commodities

被引:176
作者
Hernández, F [1 ]
Pozo, OJ [1 ]
Sancho, JV [1 ]
Bijlsma, L [1 ]
Barreda, A [1 ]
Pitarch, E [1 ]
机构
[1] Univ Jaume 1, Res Inst Pesticides & Water, Castellon de La Plana, Spain
关键词
pesticides; metabolites; multiresidue analysis; food analysis; LC-MS/MS; SPE;
D O I
10.1016/j.chroma.2006.01.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A multiresidue method is developed for the screening, quantification and confirmation of 43 pesticides, belonging to different chemical families of insecticides, acaricides, fungicides, herbicides and plant growth regulators, and 9 pesticide metabolites in four fruit and vegetable matrices. Pesticide residues are extracted from the samples with MeOH:H2O (80:20, v/v) 0.1% HCOOH, and then a cleanup step using OASIS HLB SPE cartridges is applied. The SPE eluate is concentrated and the final volume adjusted to 1 mL with MeOH:H2O (10:90, v/v) before injection into LC-MS/MS. Analyses are performed using electrospray ionization (ESI) and triple quadrupole (QqQ) analyzer. The method has been validated based on the SANCO European Guidelines for representative samples that were chosen to study the influence of different matrices: high water content (tomato), high acidic content (lemon), high sugar content (raisin) and high lipidic content (avocado). Special attention has been given to minimize the degradation of some pesticides into their metabolites and the losses observed in the evaporation step. Under the optimized conditions, the recoveries were, with a few exceptions, in the range 70-110% with satisfactory precision (CV <= 15%). The quantification of analytes was carried out using the most sensitive transition for every compound and by "matrix-matched" standards calibration. The method can be used for the accurate determination of 52 pesticides and metabolites in one single determination step at the 0.01 mg/kg level. Confirmation of residues detected in samples is performed by an independent injection into the LC-MS/MS system by acquiring additional MS/MS transitions to that used for quantification. The acquisition of the highest number of available transitions is suggested for unequivocal confirmation of the analyte. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:242 / 252
页数:11
相关论文
共 28 条
  • [1] One-year routine application of a new method based on liquid chromatography-tandem mass spectrometry to the analysis of 16 multiclass pesticides in vegetable samples
    Agüera, A
    López, S
    Fernández-Alba, AR
    Contreras, M
    Crespo, J
    Piedra, L
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) : 125 - 135
  • [2] The ECHO technique -: the more effective way of data evaluation in liquid chromatography-tandem mass spectrometry analysis
    Alder, L
    Lüderitz, S
    Lindtner, K
    Stan, HJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) : 67 - 79
  • [3] How to overcome matrix effects in the determination of pesticides in fruit by HPLC-ESI-MS-MS
    Bester, K
    Bordin, G
    Rodriguez, A
    Schimmel, H
    Pauwels, J
    Van Vyncht, G
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (04): : 550 - 555
  • [4] *EUR COMM DIR GEN, 2004, SANCO104762003 EUR C
  • [5] European Union, 2002, OFF J EUR COMMU 0821
  • [6] Monitoring multi-class pesticide residues in fresh fruits and vegetables by liquid chromatography with tandem mass spectrometry
    Frenich, AG
    Vidal, JLM
    López, TL
    Aguado, SC
    Salvador, IM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1048 (02) : 199 - 206
  • [7] Analysis of pesticides in fruit, vegetables and cereals using methanolic extraction and detection by liquid chromatography-tandem mass spectrometry
    Granby, K
    Andersen, JH
    Christensen, HB
    [J]. ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) : 165 - 176
  • [8] Evaluation of different quantitative approaches for the determination of noneasily ionizable molecules by different atmospheric pressure interfaces used in liquid chromatography tandem mass spectrometry:: Abamectin as case of study
    Grimalt, S
    Pozo, OJ
    Marín, JM
    Sancho, JV
    Hernández, F
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (10) : 1619 - 1630
  • [9] Strategies for quantification and confirmation of multi-class polar pesticides and transformation products in water by LC-MS2 using triple quadrupole and hybrid quadrupole time-of-flight analyzers
    Hernández, F
    Pozo, OJ
    Sancho, JV
    López, FJ
    Marín, JM
    Ibáñez, M
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (07) : 596 - 612
  • [10] Comparison of different mass spectrometric techniques combined with liquid chromatography for confirmation of pesticides in environmental water based on the use of identification points
    Hernández, F
    Ibáñez, M
    Sancho, JV
    Pozo, OJ
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (15) : 4349 - 4357