Accuracy, clinical correlation, and patient acceptance of two handheld prothrombin time monitoring devices in the ambulatory setting

被引:34
作者
Chapman, DC
Stephens, MA
Hamann, GL
Bailey, LE
Dorko, CS
机构
[1] Reg Med Ctr, Dept Pharm, Memphis, TN 38103 USA
[2] Univ Tennessee, Dept Internal Med, Memphis, TN USA
关键词
prothrombin time; laboratory; handheld devices;
D O I
10.1345/aph.18317
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: To evaluate the accuracy, clinical correlation, ease of use, and patient acceptance of the Coaguchek and the ProTime Microcoagulation System as compared with standard laboratory methods for prothrombin time determination, METHODS: A total of 30 prothrombin times, expressed as international normalized ratios (INRs), were determined by each handheld device for comparison with standard laboratory testing, Accuracy aas evaluated by calculating the absolute difference for each pair of INR values. Clinical correlation was defined as an INR obtained by the handheld monitor that would have resulted in the same therapeutic decision as the INR obtained by the standard laboratory method. Subjects were surveyed to determine which method of INR determination they preferred and their reasons for that preference, RESULTS: Accuracy was superior with the Coaguchek monitor. The absolute difference (mean +/- SD) in the laboratory and Coaguchek INRs was 0.28 +/- 0.23 (p = 0.96), The absolute difference (mean +/- SD) in the laboratory and the ProTime Microcoagulation System INRs was 0.56 +/- 0.34 (p < 0.001), For clinical correlation, two out of 24 (8.3%) INRs with the Coaguchek were sufficiently different from the laboratory INR to have resulted in a different therapeutic decision, compared with 12 out of 24 (50%) with the ProTime Microcoagulation System (p < 0.005), Of subjects surveyed, 77.8% preferred the finger stick method. CONCLUSIONS: The Coaguchek was superior to the ProTime Microcoagulation System in accuracy, clinical correlation, and ease of use. The study also showed that patients preferred capillary blood sampling by finger puncture over venipuncture for INR monitoring.
引用
收藏
页码:775 / 780
页数:6
相关论文
共 20 条
[1]   EVALUATION OF A PORTABLE PROTHROMBIN TIME MONITOR FOR HOME-USE BY PATIENTS WHO REQUIRE LONG-TERM ORAL ANTICOAGULANT-THERAPY [J].
ANDERSON, DR ;
HARRISON, L ;
HIRSH, J .
ARCHIVES OF INTERNAL MEDICINE, 1993, 153 (12) :1441-1447
[2]  
[Anonymous], 1998, CLIN HEMATOLOGY PRIN
[3]   PATIENT SELF-MANAGEMENT OF ORAL ANTICOAGULATION GUIDED BY CAPILLARY (FINGERSTICK) WHOLE-BLOOD PROTHROMBIN TIMES [J].
ANSELL, J ;
HOLDEN, A ;
KNAPIC, N .
ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (11) :2509-2511
[4]   COST-EFFECTIVENESS OF MONITORING WARFARIN THERAPY USING STANDARD VERSUS CAPILLARY PROTHROMBIN TIMES [J].
ANSELL, JE ;
HAMKE, AK ;
HOLDEN, A ;
KNAPIC, N .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 91 (05) :587-589
[5]  
BELSEY RE, 1991, J FAM PRACTICE, V33, P266
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
Bussey HI, 1997, PHARMACOTHERAPY, V17, P861
[8]   PERFORMANCE OF THE COUMATRAK SYSTEM IN A LARGE ANTICOAGULATION CLINIC [J].
FOULIS, PR ;
WALLACH, PM ;
ADELMAN, HM ;
SANFORD, BH ;
MCCAIN, J ;
REED, D ;
SCHLEDE, CM ;
KOKSENG, CU ;
TAYLOR, CD .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 103 (01) :98-102
[9]   EVALUATION OF THE CIBA CORNING BIOTRACK-512 COAGULATION MONITOR FOR THE CONTROL OF ORAL ANTICOAGULATION [J].
JENNINGS, I ;
LUDDINGTON, RJ ;
BAGLIN, T .
JOURNAL OF CLINICAL PATHOLOGY, 1991, 44 (11) :950-953
[10]   ACCURACY OF LABORATORY AND PORTABLE MONITOR INTERNATIONAL NORMALIZED RATIO DETERMINATIONS - COMPARISON WITH A CRITERION STANDARD [J].
KAATZ, SS ;
WHITE, RH ;
HILL, J ;
MASCHA, E ;
HUMPHRIES, JE ;
BECKER, DM .
ARCHIVES OF INTERNAL MEDICINE, 1995, 155 (17) :1861-1867