Urinary screening for methylphenidate (Ritalin) abuse: a comparison of liquid chromatography-tandem mass spectrometry, gas chromatography-mass spectrometry, and immunoassay methods

被引:34
作者
Eichhorst, J
Etter, M
Lepage, J
Lehotay, DC
机构
[1] Saskatchewan Hlth Provincial Lab, Regina, SK S4S 5W6, Canada
[2] Univ Saskatchewan, Dept Pathol, Saskatoon, SK S7N 0W0, Canada
关键词
urinary screening; methylphenidate; Ritalin;
D O I
10.1016/j.clinbiochem.2003.11.006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: To develop a routine method for detecting methylphenidate (Ritalin) use among drug abusers using liquid chromatography-tandem mass spectrometry (LC/MS/MS). The new methodology was designed to replace less reliable and/or more expensive and time-consuming techniques (GC/MS and ELISA) currently employed in our laboratory, and to provide a combined one-step screening and confirmation LC/MS/MS method. Design and methods: Because methylphenidate abuse is very prevalent in Saskatchewan, there is a demand to provide high volume urine screening both to detect abuse, and to monitor compliance. Random urine samples sent for drugs of abuse testing, standards, and controls were diluted 1:100 in methanol. Diluted specimens were injected directly into an Agilent 1100 liquid chromatograph coupled to a Sciex API 2000 mass spectrometer. The method utilized selected reaction monitoring (SRM) as well as an electrospray ionization source (EIS) to detect both urinary methylphenidate and the more prevalent metabolite, ritalinic acid (RA). Results: There appeared to be little or no sacrifice in sensitivity because the higher dilutions exhibited much less matrix effect. Limit of quantitation (LOQ) for methylphenidate was 100 nM and 500 nM for RA. Linear calibration curves from 100 to 1000 nM for Ritalin and 500 to 5000 nM for RA were acquired. Imprecision of spiked and true specimens did not exceed 10% and at the LOQ, it was less than 20%. Conclusions: A rapid, sensitive, reliable, and highly specific method by LC/MS/MS for detecting methylphenidate and its metabolite, RA, were developed. Both the cost and performance of the LC/MS/MS method were superior to GC/MS or ELISA, and it allows use of a single rapid procedure for both screening and confirmation. (C) 2003 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 7 条
[1]   Quantitative capillary electrophoresis-ion-trap mass spectrometry determination of methylphenidate in human urine [J].
Bach, GA ;
Henion, J .
JOURNAL OF CHROMATOGRAPHY B, 1998, 707 (1-2) :275-285
[2]  
BASELT RC, 2000, DISPOSITION TOXIC DR, P566
[3]  
*DIAGN LTD, 2000, SINGL STEP METHYLPHE
[4]  
Ramos L, 1999, RAPID COMMUN MASS SP, V13, P2054, DOI 10.1002/(SICI)1097-0231(19991030)13:20<2054::AID-RCM749>3.0.CO
[5]  
2-5
[6]   SIMULTANEOUS DETECTION OF METHYLPHENIDATE AND ITS MAIN METABOLITE, RITALINIC ACID, IN DOPING CONTROL [J].
SOLANS, A ;
CARNICERO, M ;
DELATORRE, R ;
SEGURA, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 658 (02) :380-384
[7]   Neuropsychopharmacological mechanisms of stimulant drug action in attention-deficit hyperactivity disorder: a review and integration [J].
Solanto, MV .
BEHAVIOURAL BRAIN RESEARCH, 1998, 94 (01) :127-152