Establishment of an in-use testing method for evaluating disinfection of surgical instruments using the duck hepatitis B model

被引:35
作者
Deva, AK [1 ]
Vickery, K [1 ]
Zou, J [1 ]
West, RH [1 ]
Harris, JP [1 ]
Cossart, YE [1 ]
机构
[1] UNIV SYDNEY,DEPT INFECT DIS,SYDNEY,NSW 2006,AUSTRALIA
基金
英国医学研究理事会;
关键词
hepatitis B virus; duck hepatitis B virus; glutaraldehyde; disinfection; surgery;
D O I
10.1016/S0195-6701(96)90096-1
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Nosocomial transmission of hepatitis B virus (HBV), associated with interventional procedures, has been attributed to its survival on improperly decontaminated instruments. To date, guidelines for chemical dis infection of potentially contaminated heat-sensitive instruments have been based largely on extrapolation of data from in-vitro disinfectant testing. Direct infectivity testing has not been possible for HBV because of the lack of a practical culture assay or susceptible experimental animal model. In this study the related duck hepadnavirus was used to simulate in-vivo transmission of a HBV during surgery, and to evaluate the effectiveness of 2% glutaraldehyde disinfection of surgical laparoscopes. Multiple laparoscopic liver biopsies were performed on 'biohazardous' duck hepatitis B (DHBV) positive ducks. Laparoscopes were then subjected to different disinfection regimes using 2% glutaraldehyde, and residual infectivity tested by placing their tips into the peritoneal cavities of uninfected four-day-old ducklings. Direct transmission of DHBV occurred in all ducks when laparoscopes were not washed. Rinsing with water lowered the transmission rate to 64% and no infection transmission occurred after 5 min of contact time with the disinfectant. In contrast, previous in-vitro studies had shown complete viral inactivation after a shorter period of disinfection. It is postulated that the longer inactivation time observed in our study may be a result of surface interactions of virus and instrument, interfering with disinfectant access or activity. Tests of instrument surface samples for viral DNA by the polymerase chain reaction (PCR) did not correlate with transmission of virus infection in vivo. PCR is an inappropriate test for evaluating the efficacy of disinfectant action despite its sensitivity. This in use method will allow testing of other decontamination procedures and their effectiveness on more complex surgical instruments.
引用
收藏
页码:119 / 130
页数:12
相关论文
共 31 条
  • [1] DETECTION OF ENTEROVIRUSES IN FECES BY POLYMERASE CHAIN-REACTION
    ABEBE, A
    JOHANSSON, B
    ABENS, J
    STRANNEGARD, O
    [J]. SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 1992, 24 (03) : 265 - 273
  • [2] HEPATITIS-B VIRUS TRANSMISSION ASSOCIATED WITH A MULTIPLE-DOSE VIAL IN A HEMODIALYSIS UNIT
    ALTER, MJ
    AHTONE, J
    MAYNARD, JE
    [J]. ANNALS OF INTERNAL MEDICINE, 1983, 99 (03) : 330 - 333
  • [3] Altman DG, 1990, PRACTICAL STAT MED R
  • [4] PRESENCE OF HUMAN-IMMUNODEFICIENCY-VIRUS NUCLEIC-ACIDS IN WASTE-WATER AND THEIR DETECTION BY POLYMERASE CHAIN-REACTION
    ANSARI, SA
    FARRAH, SR
    CHAUDHRY, GR
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1992, 58 (12) : 3984 - 3990
  • [5] AYLIFFE GAJ, 1993, GASTROINTEST ENDOSC, V3, P411
  • [6] THE MECHANICS OF ENDOSCOPE DISINFECTION
    BABB, JR
    BRADLEY, CR
    [J]. JOURNAL OF HOSPITAL INFECTION, 1991, 18 : 130 - 135
  • [7] BABB JR, 1992, INFECT SURG PRACTICE, P56
  • [8] EFFICACIES OF SELECTED DISINFECTANTS AGAINST MYCOBACTERIUM-TUBERCULOSIS
    BEST, M
    SATTAR, SA
    SPRINGTHORPE, VS
    KENNEDY, ME
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (10) : 2234 - 2239
  • [9] ENDOSCOPIC TRANSMISSION OF HEPATITIS-B VIRUS
    BIRNIE, GG
    QUIGLEY, EM
    CLEMENTS, GB
    FOLLET, EAC
    WATKINSON, G
    [J]. GUT, 1983, 24 (02) : 171 - 174
  • [10] INACTIVATION OF HEPATITIS-B VIRUS BY INTERMEDIATE-TO-HIGH-LEVEL DISINFECTANT CHEMICALS
    BOND, WW
    FAVERO, MS
    PETERSEN, NJ
    EBERT, JW
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (03) : 535 - 538