Determination of eleutheroside E and eleutheroside B in rat plasma and tissue by high-performance liquid chromatography using solid-phase extraction and photodiode array detection

被引:27
作者
Feng, SI [1 ]
di Hu, F [1 ]
Zhao, JX [1 ]
Liu, X [1 ]
Li, YU [1 ]
机构
[1] Lanzhou Univ, Dept Pharm, Cheng Guan Sect, Lanzhou 730000, Gansu, Peoples R China
关键词
eleutherococcus injection; eleutheroside E; eleutheroside B; pharmacokinetics; tissue distribution; high-performance liquid chromatography;
D O I
10.1016/j.ejpb.2005.09.007
中图分类号
R9 [药学];
学科分类号
1007 [药学];
摘要
A HPLC method with photodiode array detection (PDA) was developed for the determination and a pharmacokinetic study of eleutheroside E (ELU E) and eleutheroside B (ELU B) in rat plasma Laid tissue following an eleutherococcus injection. The analysis was performed on a Kromasil C-18 column, using water-acetonitrile as the gradient mobile phase and 0.8 rL/min flow rate. Detection wavelengths of ELU E and ELU B were 220 and 206 nm, respectively. Protein from the biological sample was deposited using acetonitrile. ELU E and ELU B were extracted from the biological samples using acetonitrile, separated by solid-phase extraction, and eluted from the cartridge using 60% methanol. The extraction recovery of ELU E and ELU B was 91.2 and 88.8%, respectively. The limit of detection was 37.6 ng/mL for ELU E and 37.0 ng/mL for ELU B (S/N=3) in plasma. Blood drug level-time cuvers of ELU E and ELU B in Wister rats following administration of an eleutherococcus injection into femoral vein were shown to fit a three-compartment model. The half-life (t(1/2)) was 4.662 h for ELU E and 2.494 h for ELU B. Following administration of a single eleutherococcus injection, the concentration of ELU E and ELU B in the tissue was C-liver> C-kidney> C-spleen> C-heart and C-kidney> C-liver> C-heart. We believe the method described in the present paper is accurate and reliable and can be used for pharmacokinetic Studies of ELU E and ELU B in rats. In addition, the method for sample preparation, using solid phase extraction, is precise, simple and rapid. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 14 条
[1]
BARENBOIM GM, 1984, KHIM FARM ZH+, V18, P493
[2]
*COMM PHARM PEOPL, 2000, PHARM PEOPL REP CHIN, V1, P491
[3]
FENG SL, 2001, CHIN J MOD APPL PHAR, V18, P124
[4]
Determination of rutin in human plasma by high-performance liquid chromatography utilizing solid-phase extraction and ultraviolet detection [J].
Ishii, K ;
Furuta, T ;
Kasuya, Y .
JOURNAL OF CHROMATOGRAPHY B, 2001, 759 (01) :161-168
[5]
*JIANGS MED COLL, 1995, DICT TRAD CHIN MED, V1, P380
[6]
Quantitative determination of eleutheroside B and E from Acanthopanax species by high performance liquid chromatography [J].
Kang, JS ;
Linh, PT ;
Cai, XF ;
Kim, HS ;
Lee, JJ ;
Kim, YH .
ARCHIVES OF PHARMACAL RESEARCH, 2001, 24 (05) :407-411
[7]
LIU LC, 2000, ANAL TEST TECHNOL IN, V6, P93
[8]
OVODOV YS, 1965, NAUK UZ SSR, V1, P3
[9]
2 GLYCOSIDE-CONTAINING GENERA OF ARALIACEAE FAMILY PANAX AND ELEUTHEROCOCCUS [J].
SANDBERG, F .
PLANTA MEDICA, 1973, 24 (04) :392-396
[10]
SOLOV'EVA A G, 1989, Farmatsiya (Moscow), V38, P25