Tissue equivalent detector data obtained recently on mir space station. Comparison with solid state detector data

被引:6
作者
BottollierDepois, JF
LebaronJacobs, L
Siegrist, M
Duvivier, E
Almarcha, B
Dachev, TP
Semkova, JV
Matviichuk, YN
Koleva, RT
Tomov, BT
Baynov, PT
Petrov, VM
Shurshakov, VV
Bengin, V
Koslova, SB
机构
[1] CNES,TOULOUSE,FRANCE
[2] STEEL TECHNOL,MAZERES SUR SALAT,FRANCE
[3] BULGARIAN ACAD SCI,SOLAR TERR INFLEUNCES LAB,SOFIA,BULGARIA
[4] MOSCOW BIOMED PROBLEMS INST,MOSCOW,RUSSIA
来源
LIFE SCIENCES: SPACE AND MARS RECENT RESULTS | 1996年 / 18卷 / 12期
关键词
D O I
10.1016/0273-1177(96)00036-1
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Tissue equivalent and Solid State Detector (SSD) measurements of the radiation environment inside the Mir space station were performed during the Antares mission in 1992 and long period after it. Interesting results about radiation measurements show (a) the South Atlantic Anomaly (SAA) crossing, (b) the increase of radiation near the poles and (c) the effects of solar eruptions (the most important one occurring in early November 1992). These data give also information about the dose and the quality factor of the radiation received by the cosmonauts during different missions. Copyright (C) 1996 COSPAR
引用
收藏
页码:171 / 174
页数:4
相关论文
共 6 条
[1]  
BENTON EV, 1986, ADV SPACE RES
[2]  
BOTTOLLIERDEPOI.JF, 1993, P 5 EUR S LIF SCI RE
[3]  
BOUISSET VD, 1992, ADV SPACE RES, V12, P363
[4]  
JANNI J, 1976, AFWLTR73222
[5]  
NGUYEN VD, 1985, RADIAT PROT DOSIM, V10, P277
[6]  
*US DEP COMM, 1992, PRF, P881