Voltammetric detection of mercury and copper in seawater using a gold microwire electrode

被引:147
作者
Salauen, Pascal [1 ]
van den Berg, Constant M. G. [1 ]
机构
[1] Univ Liverpool, Dept Earth & Ocean Sci, Liverpool L69 3GP, Merseyside, England
关键词
ANODIC-STRIPPING VOLTAMMETRY; PARTIAL CHARGE-TRANSFER; UNDERPOTENTIAL DEPOSITION; SEA-WATER; AU(111) ELECTRODE; MICROELECTRODES; ADSORPTION; PLATINUM; MARINE; METALS;
D O I
10.1021/ac060231+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure is presented by which mercury and copper are determined simultaneously in seawater and dilute acid (0.01 M HCl) by anodic stripping voltammetry using gold microwire electrodes. It was found that anion (halide) adsorption is the cause for a gradual decrease in the height and potential of the mercury peak. The effect is eliminated by including an anion desorption step in the analysis at -0.8 V prior to each scan. This step was found to greatly improve the stability of the scans and enabled the use of background subtraction. Advantages of the microwire electrodes were a low roughness of the surface, without a need for pretreatment, and a very small diffusion layer (2 mu m with stirring). Under the optimized voltammetric conditions, the detection limits were 6 pM mercury and 25 pM copper using 300-s deposition. These values are well below those reported previously for other electrodes including rotating disk electrodes. Measurements of the influence of the major anions I-, Br-, Cl-, SO42-, F-, HCO3-, and B(OH)(4) on the response for mercury showed that bromide and chloride are predominantly responsible for the underpotential deposition mechanism of mercury in seawater. The method was applied to coastal water samples from Liverpool Bay.
引用
收藏
页码:5052 / 5060
页数:9
相关论文
共 48 条
[1]   DETERMINATION OF TRACE MERCURY(II) IN 0.1 M-PERCHLORIC ACID BY DIFFERENTIAL PULSE STRIPPING VOLTAMMETRY AT A ROTATING GOLD DISK ELECTRODE [J].
ANDREWS, RW ;
LAROCHELLE, JH ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1976, 48 (01) :212-214
[2]   Hydrodynamic electrochemistry: Design for a high-speed rotating disk electrode [J].
Banks, CE ;
Simm, AO ;
Bowler, R ;
Dawes, K ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1928-1930
[3]   DIFFUSION-COEFFICIENTS DETERMINED WITH MICROELECTRODES [J].
BAUR, JE ;
WIGHTMAN, RM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 305 (01) :73-81
[4]   Gold and silver micro-wire electrodes for trace analysis of metals [J].
Billon, G ;
van den Berg, CMG .
ELECTROANALYSIS, 2004, 16 (19) :1583-1591
[5]   Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2000, 424 (01) :65-76
[6]  
Bonfil Y, 2000, REV ANAL CHEM, V19, P201
[7]   Determination of sub-μg 1-1 concentrations of copper by anodic stripping voltammetry at the gold electrode [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 1999, 387 (01) :85-95
[8]   STABILITY-CONSTANTS FOR COMPLEXATION OF COPPER(II) IONS WITH WATER AND SOIL FULVIC ACIDS MEASURED BY AN ION-SELECTIVE ELECTRODE [J].
BRESNAHAN, WT ;
GRANT, CL ;
WEBER, JH .
ANALYTICAL CHEMISTRY, 1978, 50 (12) :1675-1679
[9]   Total mercury in the water column near the shelf edge of the European continental margin [J].
Cossa, D ;
Cotté-Krief, MH ;
Mason, RP ;
Bretaudeau-Sanjuan, J .
MARINE CHEMISTRY, 2004, 90 (1-4) :21-29
[10]   The use of a remote stripping sensor for the determination of copper and mercury in the Lagoon of Venice [J].
Daniele, S ;
Bragato, C ;
Baldo, MA ;
Wang, J ;
Lu, JM .
ANALYST, 2000, 125 (04) :731-735