Common bile duct stones on multidetector computed tomography: Attenuation patterns and detectability

被引:55
作者
Kim, Chang Whan [1 ]
Chang, Jae Hyuck [1 ]
Lim, Yeon Soo [2 ]
Kim, Tae Ho [1 ]
Lee, In Seok [1 ]
Han, Sok Won [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Internal Med, Seoul 137701, South Korea
[2] Catholic Univ Korea, Coll Med, Dept Radiol, Seoul 137701, South Korea
关键词
Common bile duct gallstones; Gallstones; Multidetector computed tomography; Endoscopic retrograde cholangiography; ENDOSCOPIC ULTRASONOGRAPHY; HELICAL CT; DIAGNOSING CHOLEDOCHOLITHIASIS; IN-VITRO; BILIARY; COMPLICATIONS; GALLSTONES; ACCURACY; CONTRAST; CHOLANGIOGRAPHY;
D O I
10.3748/wjg.v19.i11.1788
中图分类号
R57 [消化系及腹部疾病];
学科分类号
100201 [内科学];
摘要
AIM: To investigate the attenuation patterns and detectability of common bile duct (CBD) stones by multidetector computed tomography (MDCT). METHODS: Between March 2010 and February 2012, 191 patients with suspicion of CBD stones undergoing both MDCT and endoscopic retrograde cholangiopancreatography (ERCP) were enrolled and reviewed retrospectively. The attenuation patterns of CBD stones on MDCT were classified as heavily calcified, radiopaque, less radiopaque, or undetectable. The association between the attenuation patterns of CBD stones on MDCT and stone type consisting of pure cholesterol, mixed cholesterol, brown pigment, and black pigment and the factors related to the detectability of CBD stones by MDCT were evaluated. RESULTS: MDCT showed CBD stones in 111 of 130 patients in whom the CBD stones were demonstrated by ERCP with 85.4% sensitivity. The attenuation patterns of CBD stones on MDCT were heavily calcified 34 (26%), radiopaque 31 (24%), less radiopaque 46 (35%), and undetectable 19 (15%). The radiopacity of CBD stones differed significantly according to stone type (P < 0.001). From the receiver operating characteristic curve, stone size was useful for the determination of CBD stone by MDCT (area under curve 0.779, P < 0.001) and appropriate cut-off stone size on MDCT was 5 mm. The factors related to detectability of CBD stones on MDCT were age, stone type, and stone size on multivariate analysis (P < 0.05). CONCLUSION: The radiopacity of CBD stones on MDCT differed according to stone type. Stone type and stone size were related to the detectability by MDCT, and appropriate cut-off stone size was 5 mm. (C) 2013 Baishideng. All rights reserved.
引用
收藏
页码:1788 / 1796
页数:9
相关论文
共 34 条
[1]
Is there a difference in diagnostic accuracy and clinical impact between endoscopic ultrasonography and magnetic resonance cholangiopancreatography? [J].
Ainsworth, AP ;
Rafaelsen, SR ;
Wamberg, PA ;
Durup, J ;
Pless, TK ;
Mortensen, MB .
ENDOSCOPY, 2003, 35 (12) :1029-1032
[2]
Detection of biliary duct narrowing and choledocholithiasis: Accuracy of portal venous phase multidetector CT [J].
Anderson, Stephan W. ;
Rho, Eunjin ;
Soto, Jorge A. .
RADIOLOGY, 2008, 247 (02) :418-427
[3]
64-Detector Row Computed Tomography: An Improved Tool for Evaluating the Biliary and Pancreatic Ducts? [J].
Anderson, Stephan W. ;
Zajick, Donald ;
Lucey, Brian C. ;
Soto, Jorge A. .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2007, 36 (06) :258-271
[4]
Accuracy diagnosis of MDCT in the of choledocholithiasis [J].
Anderson, SW ;
Lucey, BC ;
Varghese, JC ;
Soto, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) :174-180
[5]
[Anonymous], 2002, NIH Consens State Sci Statements, V19, P1
[6]
Diagnosing choledocholithiasis: How far can we push helical CT? [J].
Baron, RL .
RADIOLOGY, 1997, 203 (03) :601-603
[7]
CT EVALUATION OF GALLSTONES INVITRO - CORRELATION WITH CHEMICAL-ANALYSIS [J].
BARON, RL ;
ROHRMANN, CA ;
LEE, SP ;
SHUMAN, WP ;
TEEFEY, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (06) :1123-1128
[8]
PREDICTING GALLSTONE COMPOSITION WITH CT - INVIVO AND INVITRO ANALYSIS [J].
BRAKEL, K ;
LAMERIS, JS ;
NIJS, HGT ;
TERPSTRA, OT ;
STEEN, G ;
BLIJENBERG, BC .
RADIOLOGY, 1990, 174 (02) :337-341
[9]
Endoscopic ultrasonography versus cholangiography for the diagnosis of choledocholithiasis [J].
Canto, MIF ;
Chak, A ;
Stellato, T ;
Sivak, MV .
GASTROINTESTINAL ENDOSCOPY, 1998, 47 (06) :439-448
[10]
Gallstone detection at CT in vitro: Effect of peak voltage setting [J].
Chan, Wesley C. ;
Joe, Bonnie N. ;
Coakley, Fergus V. ;
Prien, Edwin L. ;
Gould, Robert G. ;
Prevrhal, Sven ;
Barber, William C. ;
Kirkwood, Kimberley S. ;
Qayyum, Aliya ;
Yeh, Benjamin M. .
RADIOLOGY, 2006, 241 (02) :546-553