Quantitative measurements of cerebral blood flow in patients with unilateral carotid artery occlusion: A PET and MR study

被引:83
作者
Lin, W [1 ]
Celik, A [1 ]
Derdeyn, C [1 ]
An, H [1 ]
Lee, Y [1 ]
Videen, T [1 ]
Ostergaard, L [1 ]
Powers, WJ [1 ]
机构
[1] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
关键词
cerebral blood flow; cerebrovascular disease; perfusion imaging; PET; MRI;
D O I
10.1002/jmri.10021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although it has been demonstrated that quantitative measures of cerebral blood flow (CBF) can be obtained with the singular value decomposition (SVD) algorithm, the extent to which quantitative CBF measurements can be utilized under pathophysiological conditions has not been systematically studied. A total of five healthy volunteers and five patients with unilateral carotid artery occlusion were studied. Only magnetic resonance (MR) images were acquired for the volunteer group while both MR and positron emission tomography (PET) Images were acquired for the patient group. Assessments of CBF from normal volunteers compared favorably with values reported in the literature. However, while a linear relationship was observed for each patient when MR measured CBF was compared to that obtained from PET, this linear relationship diminished when all patients were analyzed as a group (r = 0.41). A correction factor (CF) was proposed that was equal to the ratio of the area of the venous output function (VOF) in each patient to the mean VOF obtained from the volunteer group. After globally scaling the CBF of each patient based on the experimentally derived CF, a substantial improvement was observed (a slope of 1.02 and r = 0.8 for the linear regression line) in the relationship between AIR estimated CBF and those obtained from PET. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:659 / 667
页数:9
相关论文
共 28 条
[1]   CEREBRAL BLOOD-VOLUME MAPS OF GLIOMAS - COMPARISON WITH TUMOR GRADE AND HISTOLOGIC-FINDINGS [J].
ARONEN, HJ ;
GAZIT, IE ;
LOUIS, DN ;
BUCHBINDER, BR ;
PARDO, FS ;
WEISSKOFF, RM ;
HARSH, GR ;
COSGROVE, GR ;
HALPERN, EF ;
HOCHBERG, FH ;
ROSEN, BR .
RADIOLOGY, 1994, 191 (01) :41-51
[2]   THE INTRAVASCULAR CONTRIBUTION TO FMRI SIGNAL CHANGE - MONTE-CARLO MODELING AND DIFFUSION-WEIGHTED STUDIES IN-VIVO [J].
BOXERMAN, JL ;
BANDETTINI, PA ;
KWONG, KK ;
BAKER, JR ;
DAVIS, TL ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :4-10
[3]   Increased oxygen extraction fraction is associated with prior ischemic events in patients with carotid occlusion [J].
Derdeyn, CP ;
Yundt, KD ;
Videen, TO ;
Carpenter, DA ;
Grubb, RL ;
Powers, WJ .
STROKE, 1998, 29 (04) :754-758
[4]   Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease [J].
Detre, JA ;
Alsop, DC ;
Vives, LR ;
Maccotta, L ;
Teener, JW ;
Raps, EC .
NEUROLOGY, 1998, 50 (03) :633-641
[5]   Importance of hemodynamic factors in the prognosis of symptomatic carotid occlusion [J].
Grubb, RL ;
Derdeyn, CP ;
Fritsch, SM ;
Carpenter, DA ;
Yundt, KD ;
Videen, TO ;
Spitznagel, EL ;
Powers, WJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (12) :1055-1060
[6]  
GUCKEL F, 1994, J COMPUT ASSIST TOMO, V18, P344, DOI 10.1097/00004728-199405000-00002
[7]   MEASUREMENT OF CEREBROVASCULAR CHANGES IN CATS AFTER TRANSIENT ISCHEMIA USING DYNAMIC MAGNETIC-RESONANCE-IMAGING [J].
HAMBERG, LM ;
MACFARLANE, R ;
TASDEMIROGLU, E ;
BOCCALINI, P ;
HUNTER, GJ ;
BELLIVEAU, JW ;
MOSKOWITZ, MA ;
ROSEN, BR .
STROKE, 1993, 24 (03) :444-451
[8]   POSITRON EMISSION TOMOGRAPHIC MEASUREMENT OF CEREBRAL BLOOD-FLOW AND PERMEABILITY SURFACE-AREA PRODUCT OF WATER USING [O-15]WATER AND [C-11] BUTANOL [J].
HERSCOVITCH, P ;
RAICHLE, ME ;
KILBOURN, MR ;
WELCH, MJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1987, 7 (05) :527-542
[9]  
HERSCOVITCH P, 1983, J NUCL MED, V24, P782
[10]   Quantitative perfusion imaging in carotid artery stenosis using dynamic susceptibility contrast-enhanced magnetic resonance imaging [J].
Lythgoe, DJ ;
Ostergaard, L ;
Williams, SCR ;
Cluckie, A ;
Buxton-Thomas, M ;
Simmons, A ;
Markus, HS .
MAGNETIC RESONANCE IMAGING, 2000, 18 (01) :1-11