Capillary gas chromatographic analysis of nerve agents using large volume injections

被引:22
作者
DegenhardtLangelaan, CEAM
Kientz, CE
机构
[1] TNO Prins Maurits Laboratory, 2280 AA Rijswijk
关键词
large volume injection; organophosphorus compounds; sarin; tabun; soman; DFP; VX; chemical warfare agents;
D O I
10.1016/0021-9673(95)00822-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of large volume injections has been studied for the verification of intact organophosphorus chemical warfare agents in water samples. As the use of ethyl acetate caused severe detection problems new potential solvents were evaluated. With the developed procedure, the nerve agents sarin, tabun, soman, DFP and VX can be determined in freshly prepared water samples at ppt levels. Except for the nerve agent tabun all other agents added to the water samples were still present after 8 days at 20-60% levels, if the pH of the water sample is adjusted to ca. 5 shortly after sampling and adjusted to pH 7 for analysis.
引用
收藏
页码:210 / 214
页数:5
相关论文
共 20 条
[1]  
[Anonymous], CONV PROH DEV PROD S
[2]  
EPSTEIN J, 1974, PHOSPHORUS, V4, P157
[3]   ON-COLUMN INJECTION OF LARGE SAMPLE VOLUMES USING THE RETENTION GAP TECHNIQUE IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K ;
KARRER, G ;
RIEKKOLA, ML .
JOURNAL OF CHROMATOGRAPHY, 1985, 334 (02) :129-155
[4]  
GROB K, 1987, COLUMN INJECTION CAP
[5]  
GROB K, 1987, J HIGH RES CHROMATOG, V10, P440
[6]   VERIFICATION OF NONPRODUCTION OF CHEMICAL WARFARE AGENTS .1. DETERMINATION OF ORGANOPHOSPHORUS COMPOUNDS BY MICROCOLUMN LIQUID-CHROMATOGRAPHY WITH FLAME PHOTOMETRIC OR THERMIONIC DETECTION [J].
KIENTZ, CE ;
VERWEIJ, A ;
DEJONG, GJ ;
BRINKMAN, UAT .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1992, 4 (06) :465-475
[7]  
KINETZ CE, 1992, J MICROCOLUMN SEP, V4, P476
[8]   DETERMINATION OF ORGANOPHOSPHORUS PESTICIDES IN AQUEOUS SAMPLES BY ONLINE MEMBRANE DISK EXTRACTION AND CAPILLARY GAS-CHROMATOGRAPHY [J].
KWAKMAN, PJM ;
VREULS, JJ ;
BRINKMAN, UAT ;
GHIJSEN, RT .
CHROMATOGRAPHIA, 1992, 34 (1-2) :41-47
[9]   FULLY AUTOMATED WATER ANALYZER BASED ON ONLINE SOLID-PHASE EXTRACTION GAS-CHROMATOGRAPHY [J].
LOUTER, AJH ;
BRINKMAN, UAT ;
GHIJSEN, RT .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (04) :303-315
[10]   ANALYSIS OF PETROLEUM FRACTIONS BY ONLINE MICRO HPLC-HRGC COUPLING, INVOLVING INCREASED EFFICIENCY IN USING RETENTION GAPS BY PARTIALLY CONCURRENT SOLVENT EVAPORATION [J].
MUNARI, F ;
TRISCIANI, A ;
MAPELLI, G ;
TRESTIANU, S ;
GROB, K ;
COLIN, JM .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1985, 8 (09) :601-606