Coapsys mitral annuloplasty for chronic functional ischemic mitral regurgitation: 1-year results

被引:62
作者
Mishra, YK [1 ]
Mittal, S
Jaguri, P
Trehan, N
机构
[1] Escorts Heart Inst & Res Ctr, Dept Cardiac Surg, New Delhi, India
[2] Escorts Heart Inst & Res Ctr, Dept Cardiol, New Delhi, India
关键词
D O I
10.1016/j.athoracsur.2005.06.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Untreated functional ischemic mitral regurgitation (MR) leads to reduced survival in patients undergoing coronary artery bypass grafting (CABG). However, mitral repair or replacement increases mortality and morbidity over CABG alone. The Myocor Coapsys annuloplasty system potentially reduces these risks by facilitating MR reduction on a beating heart without atriotomy. We present data from the first 11 patients completing 1-year follow-up of a total of 34 implanted patients. Methods. Patients referred for CABG with preoperative grade 2 or greater ischemic functional MR were included in this study. Patients with structural valve defects or who demonstrated MR less than grade 2 after CABG, despite hemodynamic challenge, were intraoperatively excluded. Coapsys consists of two epicardial pads connected by a flexible chord implanted by passing the chord across the left ventricle with special instruments without cardiopulmonary bypass. The system was sized to reduce critical valve dimensions and MR. Serial clinical and echocardiographic data were collected out to 1 year. Results. Mean age was 58.1 +/- 6.6 years and mean ejection fraction, 38.5% +/- 7.1%. From baseline to 1-year follow-up, effect on MR grade, MR jet area (cm(2)), and New York Heart Association class were, respectively, 2.9 +/- 0.5 to 1.1 +/- 0.8, 7.4 +/- 2.9 to 3.0 +/- 1.6, and 2.5 +/- 0.5 to 1.2 +/- 0.4 (all p < 0.05 versus baseline). During follow-up, there were no deaths, device failures, reemergence of grade 3 or 4 MR, heart failure readmission, or valve reoperations. Conclusions. The Coapsys annuloplasty system is effective in reducing functional ischemic MR and improving NYHA class. The initial data are encouraging and suggest that the device is safe and benefits are sustained at 1 year.
引用
收藏
页码:42 / 46
页数:5
相关论文
共 23 条
[1]  
Aklog L, 2001, CIRCULATION, V104, pI68
[2]   Intermediate-term outcome of mitral reconstruction in cardiomyopathy [J].
Bolling, SF ;
Pagani, FD ;
Deeb, GM ;
Bach, DS .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (02) :381-386
[3]  
Dion R, 1995, J HEART VALVE DIS S2, V4, P124
[4]   Changes in mitral annular and left ventricular dimensions and left ventricular pressure-volume relations after off-pump treatment of mitral regurgitation with the Coapsys device [J].
Fukamachi, K ;
Popovic, ZB ;
Inoue, M ;
Doi, K ;
Schenk, S ;
Ootaki, Y ;
Kopcak, MW ;
McCarthy, PM .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (03) :352-357
[5]   Off-pump mitral valve repair using the coapsys device: A pilot study in a pacing-induced mitral regurgitation model [J].
Fukamachi, K ;
Inoue, M ;
Popovic, ZB ;
Doi, K ;
Schenk, S ;
Nemeh, H ;
Ootaki, Y ;
Kopcak, MW ;
Dessoffy, R ;
Thomas, JD ;
Bianco, RW ;
Berry, JM ;
McCarthy, PM .
ANNALS OF THORACIC SURGERY, 2004, 77 (02) :688-692
[6]   Does the additive risk of mitral valve repair in patients with ischemic cardiomyopathy prohibit surgical intervention? [J].
Gangemi, JJ ;
Tribble, CG ;
Ross, SD ;
McPherson, JA ;
Kern, JA ;
Kron, IL .
ANNALS OF SURGERY, 2000, 231 (05) :710-713
[7]   MITRAL-VALVE REPAIR FOR ISCHEMIC MITRAL-INSUFFICIENCY [J].
HENDREN, WG ;
NEMEC, JJ ;
LYTLE, BW ;
LOOP, FD ;
TAYLOR, PC ;
STEWART, RW ;
COSGROVE, DM .
ANNALS OF THORACIC SURGERY, 1991, 52 (06) :1246-1252
[8]   Reverse ventricular remodeling reduces ischemic mitral regurgitation - Echo-guided device application in the beating heart [J].
Hung, J ;
Guerrero, JL ;
Handschumacher, MD ;
Supple, G ;
Sullivan, S ;
Levine, RA .
CIRCULATION, 2002, 106 (20) :2594-2600
[9]   Papillary muscle sling: A new functional approach to mitral repair in patients with ischemic left ventricular dysfunction and functional mitral regurgitation [J].
Hvass, U ;
Tapia, M ;
Baron, F ;
Pouzet, B ;
Shafy, A .
ANNALS OF THORACIC SURGERY, 2003, 75 (03) :809-811
[10]   Mitral valve repair without cardiopulmonary bypass or atriotomy using the Coapsys device: Device design and implantation procedure in canine functional mitral regurgitation model [J].
Inoue, M ;
McCarthy, PM ;
Popovic, ZB ;
Doi, K ;
Schenk, S ;
Nemeh, H ;
Ootaki, Y ;
Kopcak, MW ;
Dessoffy, R ;
Thomas, JD ;
Fukamachi, K .
HEART SURGERY FORUM, 2004, 7 (02) :E117-E121