Stability of doubly-fed induction generator under stator voltage orientated vector control

被引:55
作者
Chondrogionnis, S. [1 ]
Barnes, M. [1 ]
机构
[1] Univ Manchester, Sch Elect & Elect Engn, Manchester M60 1QD, Lancs, England
关键词
D O I
10.1049/iet-rpg:20070086
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
The stability of a doubly-fed induction generator (DFIG) under vector control in stator voltage orientation (SVO) is investigated. Prior art has tended to assume that the inner current loop dynamics can be neglected when an SVO is employed. As a result, the poorly damped poles of the DFIG system were considered unaffected by the inner current loop tuning. The state-space model of the machine including the inner current closed loop dynamics is developed for schemes where different feed-forward compensation terms are used. The interaction between inner current loop dynamics and damping of the critical poles of the system is illustrated through analysis and simulation. The main outcome of the analysis is that the stability of the machine system in an SVO depends solely on the parameters of the proportional-integral controllers. Erroneous tuning can lead to instability, irrespective of the particular feed-forward compensation scheme, which could cause the disconnection of the machine as a result of rotor current oscillations of unacceptable magnitude in an actual case. The main contribution is to provide the necessary methodology in order to ensure the stable operation of a DFIG under SVO vector control.
引用
收藏
页码:170 / 180
页数:11
相关论文
共 14 条
[1]
Performance of Doubly Fed Induction Generator (DFIG) During Network Faults [J].
Anaya-Lara, O. ;
Wu, X. ;
Cartwright, P. ;
Ekanayake, J. ;
Jenkins, N. .
WIND ENGINEERING, 2005, 29 (01) :49-66
[2]
Control of DFIG wind turbines [J].
Ekanayake, J ;
Holdsworth, L ;
Jenkins, N .
POWER ENGINEER, 2003, 17 (01) :28-32
[3]
Dynamic modeling of doubly fed induction generator wind turbines [J].
Ekanayake, JB ;
Holdsworth, L ;
Wu, XG ;
Jenkins, N .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (02) :803-809
[4]
FRANKLIN GF, DYNAMIC MODELS DYNAM, P73
[5]
FRANKLIN GF, DYNAMIC MODELS DYNAM, P78
[6]
Hansen A. D., 2004, Wind Engineering, V28, P411, DOI 10.1260/0309524042886441
[7]
Hansen L H., 2001, CONCEPTUAL SURVEY GE
[8]
Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder [J].
Hopfensperger, B ;
Atkinson, DJ ;
Lakin, RA .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2000, 147 (04) :241-250
[9]
Liu CW, 2001, ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, P1203, DOI 10.1109/ICEMS.2001.971897
[10]
Power-electronic systems for the grid integration of renewable energy sources:: A survey [J].
Manuel Carrasco, Juan ;
Franquelo, Leopoldo G. ;
Bialasiewicz, Jan T. ;
Galvan, Eduardo ;
Portillo, Ramon ;
Martin Prats, Maria ;
Ignacio Leon, Jose ;
Moreno-Alfonso, Narciso .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (04) :1002-1016