Continuous cardiac output monitoring by peripheral blood pressure waveform analysis

被引:98
作者
Mukkamala, R [1 ]
Reisner, AT
Hojman, HM
Mark, RG
Cohen, RJ
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Massachusetts Gen Hosp, Dept Emergency Med, Boston, MA 02114 USA
[3] Yale Univ, Sch Med, Dept Surg, New Haven, CT 06519 USA
[4] Harvard Univ, MIT, Div Hlth Sci & Technol, Cambridge, MA 02139 USA
关键词
arterial blood pressure; arterial tree; cardiac output; distributed effects; hemodynamics; mathematical modeling; pulse contour analysis; system identification; wave reflections; Windkessel;
D O I
10.1109/TBME.2005.869780
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A clinical method for monitoring cardiac output (CO) should be continuous, minimally invasive, and accurate. However, none of the conventional CO measurement methods possess all of these characteristics. On the other hand, peripheral arterial blood pressure (ABP) may be measured reliably and continuously with little or no invasiveness. We have developed a novel technique for continuously monitoring changes in CO by mathematical analysis of a peripheral ABP waveform. In contrast to the previous techniques, our technique analyzes the ABP waveform over time scales greater than a cardiac cycle in which the confounding effects of complex wave reflections are attenuated. The technique specifically analyzes 6-min intervals of ABP to estimate the pure exponential pressure decay that would eventually result if pulsatile activity abruptly ceased (i.e., after the high frequency wave reflections vanish). The technique then determines the time constant of this exponential decay, which equals the product of the total peripheral resistance and the nearly constant arterial compliance, and computes proportional CO via Ohm's law. To validate the technique, we performed six acute swine experiments in which peripheral ABP waveforms and aortic flow probe CO were simultaneously measured over a wide physiologic range. We report an overall CO error of 14.6%.
引用
收藏
页码:459 / 467
页数:9
相关论文
共 28 条
[1]   BEAT TO BEAT VARIABILITY IN CARDIOVASCULAR VARIABLES - NOISE OR MUSIC [J].
APPEL, ML ;
BERGER, RD ;
SAUL, JP ;
SMITH, JM ;
COHEN, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) :1139-1148
[2]   CHARACTERISTICS OF AORTIC DIASTOLIC PRESSURE DECAY WITH APPLICATION TO CONTINUOUS MONITORING OF CHANGES IN PERIPHERAL VASCULAR-RESISTANCE [J].
BOURGEOIS, MJ ;
GILBERT, BK ;
DONALD, DE ;
WOOD, EH .
CIRCULATION RESEARCH, 1974, 35 (01) :56-66
[3]   CONTINUOUS DETERMINATION OF BEAT-TO-BEAT STROKE VOLUME FROM AORTIC PRESSURE PULSES IN DOG [J].
BOURGEOIS, MJ ;
GILBERT, BK ;
BERNUTH, GV ;
WOOD, EH .
CIRCULATION RESEARCH, 1976, 39 (01) :15-24
[4]   Beat-to-beat stroke volume estimation from aortic pressure waveform in conscious rats: comparison of models [J].
Cerutti, C ;
Gustin, MP ;
Molino, P ;
Paultre, CZ .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 281 (03) :H1148-H1155
[5]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[6]   CLINICAL COMPARISON OF PRESSURE-PULSE AND INDICATOR-DILUTION CARDIAC-OUTPUT DETERMINATION [J].
CUNDICK, RM ;
GARDNER, RM .
CIRCULATION, 1980, 62 (02) :371-376
[7]   CARDIAC-OUTPUT MEASUREMENTS - A REVIEW OF CURRENT TECHNIQUES AND RESEARCH [J].
EHLERS, KC ;
MYLREA, KC ;
WATERSON, CK ;
CALKINS, JM .
ANNALS OF BIOMEDICAL ENGINEERING, 1986, 14 (03) :219-239
[8]  
Erlanger J, 1904, JOHNS HOPKINS HOSP R, V12, P145
[9]   CONTINUOUS NONINVASIVE CARDIAC-OUTPUT AS ESTIMATED FROM THE PULSE CONTOUR CURVE [J].
GRATZ, I ;
KRAIDIN, J ;
JACOBI, AG ;
DECASTRO, NG ;
SPAGNA, P ;
LARIJANI, GE .
JOURNAL OF CLINICAL MONITORING, 1992, 8 (01) :20-27
[10]   Studies on the elastic properties of human isolated aorta [J].
Hallock, P ;
Benson, IC .