Palamed G compared with Palacos R with gentamicin in Charnley total hip replacement

被引:14
作者
Hallan, G. [1 ]
Aamodt, A. [1 ]
Furnes, O. [1 ]
Skredderstuen, A. [1 ]
Haugan, K. [1 ]
Havelin, L. I. [1 ]
机构
[1] Haukeland Hosp, Dept Orthopaed Surg, N-5021 Bergen, Norway
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2006年 / 88B卷 / 09期
关键词
D O I
10.1302/0301-620X.88B9.18008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We performed a randomised, radiostereometric study comparing two different bone cements, one of which has been sparsely clinically documented. Randomisation of 60 total hip replacements (57 patients) into two groups of 30 was undertaken. All the patients were operated on using a cemented Charnley total hip replacement, the only difference between groups being the bone cement used to secure the femoral component. The two cements used were Palamed G and Palacos R with gentamicin. The patients were followed up with repeated clinical and radiostereometric examinations for two years to assess the micromovement of the femoral component and the clinical outcome. The mean subsidence was 0.18 mm and 0.21 mm, and the mean internal rotation was 1.7 degrees and 2.0 degrees at two years for the Palamed G and Palacos R with gentamicin bone cements, respectively. We found no statistically significant differences between the groups. Micromovement occurred between the femoral component and the cement, while the cement mantle was stable inside the bone. The Harris hip score improved from a mean of 38 points (14 to 54) and 36 (10 to 57) pre-operatively to a mean of 92 (77 to 100) and 91 (63 to 100) at two years in the Palamed G and Palacos R groups, respectively. No differences were found between the groups. Both bone cements provided good initial fixation of the femoral component and good clinical results at two years.
引用
收藏
页码:1143 / 1148
页数:6
相关论文
共 30 条
[1]
Cement migration after THR -: A comparison of Charnley Elite and Exeter femoral stems using RSA [J].
Alfaro-Adrián, J ;
Gill, HS ;
Murray, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :130-134
[2]
BALLARD WT, 1994, J BONE JOINT SURG AM, V76A, P959
[3]
The type of cement and failure of total hip replacements [J].
Espehaug, B ;
Furnes, O ;
Havelin, LI ;
Engesæter, LB ;
Vollset, SE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (06) :832-838
[4]
EARLY MIGRATION AND LATE ASEPTIC FAILURE OF PROXIMAL FEMORAL PROSTHESES [J].
FREEMAN, MAR ;
PLANTEBORDENEUVE, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :432-438
[5]
Exeter and Charnley arthroplasties with Boneloc or high viscosity cement - Comparison of 1,127 arthroplasties followed for 5 years in the Norwegian Arthroplasty Register [J].
Furnes, O ;
Lie, SA ;
Havelin, LI ;
Vollset, SE ;
Engesaeter, LB .
ACTA ORTHOPAEDICA SCANDINAVICA, 1997, 68 (06) :515-520
[6]
The effect of anteversion on femoral component stability assessed by radiostereometric analysis [J].
Gill, HS ;
Alfaro-Adrián, J ;
Alfaro-Adrián, C ;
McLardy-Smith, P ;
Murray, DW .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :997-1005
[7]
Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem - A randomized study with use of radio stereometry and bone densitometry [J].
Grant, P ;
Aamodt, A ;
Falch, JA ;
Nordsletten, L .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (06) :1280-1285
[8]
THE DIRECT LATERAL APPROACH TO THE HIP [J].
HARDINGE, K .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (01) :17-19
[10]
THE EFFECT OF THE TYPE OF CEMENT ON EARLY REVISION OF CHARNLEY TOTAL HIP PROSTHESES - A REVIEW OF 8,579 PRIMARY ARTHROPLASTIES FROM THE NORWEGIAN ARTHROPLASTY REGISTER [J].
HAVELIN, LI ;
ESPEHAUG, B ;
VOLLSET, SE ;
ENGESAETER, LB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (10) :1543-1550