Mass sensitive detection of carbon dioxide by amino group-functionalized polymers

被引:35
作者
Zhou, R
Schmeisser, D
Gopel, W
机构
[1] Inst. of Phys. and Theor. Chemistry, Ctr. of Interface Anal. and Sensors, University of Tubingen, D-72076 Tübingen
[2] Fritz-Haber-Institut, Max-Planck-Society, Berlin
[3] Fritz-Haber-Institut, IBM-Research-Center, Yorktown Heights, NY
[4] Hahn-Meitner-Institut, Berlin
[5] Department of Physics, Ctr. of Surf. and Submicron Analysis, Bozeman, MT
关键词
carbon dioxide detection; quartz microbalance; polymers;
D O I
10.1016/0925-4005(96)80096-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A series of amino group-functionalized polymers was investigated as sensitive coatings for the detection of carbon dioxide in the gas phase by using quartz microbalance transducers. The sensor signals are reversible with response and decay times in the order of minutes at operating temperatures between 25 degrees C and 70 degrees C. The long term stability and the cross sensitivities to other gases are also discussed.
引用
收藏
页码:188 / 193
页数:6
相关论文
共 19 条
  • [1] BODENHOFER K, 1996, IN PRESS SENSORS A B
  • [2] AMPEROMETRIC SENSOR FOR CARBON-DIOXIDE - DESIGN, CHARACTERISTICS, AND PERFORMANCE
    EVANS, J
    PLETCHER, D
    WARBURTON, PRG
    GIBBS, TK
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (06) : 577 - 580
  • [3] FARQUE AM, 1992, EUR POLYM J, V28, P1579
  • [4] PIEZOELECTRIC CRYSTAL MONITOR FOR CARBON-DIOXIDE IN FERMENTATION PROCESSES
    FATIBELLOFILHO, O
    DEANDRADE, JF
    SULEIMAN, AA
    GUILBAULT, GG
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (07) : 746 - 748
  • [5] AMPEROMETRIC-TYPE SENSOR FOR CO2 USING BACEO3-BASED CERAMIC
    HIBINO, T
    IWAHARA, H
    [J]. CHEMISTRY LETTERS, 1992, (07) : 1221 - 1224
  • [6] IN J, 1992, 4 INT M CHEM SENS TO
  • [7] APPLICATION OF MIXED-OXIDE CAPACITOR TO THE SELECTIVE CARBON-DIOXIDE SENSOR .1. MEASUREMENT OF CARBON-DIOXIDE SENSING CHARACTERISTICS
    ISHIHARA, T
    KOMETANI, K
    HASHIDA, M
    TAKITA, Y
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1991, 138 (01) : 173 - 176
  • [8] SELECTIVITY CHARACTERISTICS OF POTENTIOMETRIC CARBON-DIOXIDE SENSORS WITH VARIOUS GAS MEMBRANE MATERIALS
    KOBOS, RK
    PARKS, SJ
    MEYERHOFF, ME
    [J]. ANALYTICAL CHEMISTRY, 1982, 54 (12) : 1976 - 1980
  • [9] LANG T, 1995, P C TRQANSD STOCKH
  • [10] QUARTZ MICROBALANCE SENSORS FOR GAS-DETECTION
    LUCKLUM, R
    HENNING, B
    HAUPTMANN, P
    SCHIERBAUM, KD
    VAIHINGER, S
    GOPEL, W
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1991, 27 (1-3) : 705 - 710