Bias Atlases for Segmentation-Based PET Attenuation Correction Using PET-CT and MR

被引:36
作者
Ouyang, Jinsong [1 ,2 ]
Chun, Se Young [2 ,3 ]
Petibon, Yoann [1 ,4 ]
Bonab, Ali A. [1 ,2 ]
Alpert, Nathaniel [1 ,2 ]
El Fakhri, Georges [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Ctr Adv Radiol Sci, Div Nucl Med & Mol Imaging, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Boston, MA 02114 USA
[4] Univ Paris 06, INSERM, UMR S 678, Lab Imagerie Fonct, F-75634 Paris, France
基金
美国国家卫生研究院;
关键词
Attenuation correction; PET-MR; WHOLE-BODY PET/MRI; IMAGE REGISTRATION; DISEASE;
D O I
10.1109/TNS.2013.2278624
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study was to obtain voxel-wise PET accuracy and precision using tissue-segmentation for attenuation correction. We applied multiple thresholds to the CTs of 23 patients to classify tissues. For six of the 23 patients, MR images were also acquired. The MR fat/in-phase ratio images were used for fat segmentation. Segmented tissue classes were used to create attenuation maps, which were used for attenuation correction in PET reconstruction. PET bias images were then computed using the PET reconstructed with the original CT as the reference. We registered the CTs for all the patients and transformed the corresponding bias images accordingly. We then obtained the mean and standard deviation bias atlas using all the registered bias images. Our CT-based study shows that four-class segmentation (air, lungs, fat, other tissues), which is available on most PET-MR scanners, yields 15.1%, 4.1%, 6.6%, and 12.9% RMSE bias in lungs, fat, non-fat soft-tissues, and bones, respectively. An accurate fat identification is achievable using fat/in-phase MR images. Furthermore, we have found that three-class segmentation (air, lungs, other tissues) yields less than 5% standard deviation of bias within the heart, liver, and kidneys. This implies that three-class segmentation can be sufficient to achieve small variation of bias for imaging these three organs. Finally, we have found that inter- and intra-patient lung density variations contribute almost equally to the overall standard deviation of bias within the lungs.
引用
收藏
页码:3373 / 3382
页数:10
相关论文
共 34 条
[1]   Magnetic resonance imaging of pulmonary parenchymal disease using a modified breath-hold 3D gradient-echo technique: Initial observations [J].
Bader, TR ;
Semelka, RC ;
Pedro, MS ;
Armao, DM ;
Brown, MA ;
Molina, PL .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (01) :31-38
[2]   A generalized model for the conversion from CT numbers to linear attenuation coefficients [J].
Bai, CY ;
Shao, L ;
Da Silva, AJ ;
Zhao, Z .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1510-1515
[3]   MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence [J].
Berker, Yannick ;
Franke, Jochen ;
Salomon, Andre ;
Palmowski, Moritz ;
Donker, Henk C. W. ;
Temur, Yavuz ;
Mottaghy, Felix M. ;
Kuhl, Christiane ;
Izquierdo-Garcia, David ;
Fayad, Zahi A. ;
Kiessling, Fabian ;
Schulz, Volkmar .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (05) :796-804
[4]   MR-based attenuation correction for torso-PET/MR imaging:: pitfalls in mapping MR to CT data [J].
Beyer, Thomas ;
Weigert, Markus ;
Quick, Harald H. ;
Pietrzyk, Uwe ;
Vogt, Florian ;
Palm, Christoph ;
Antoch, Gerald ;
Mueller, Stefan P. ;
Bockisch, Andreas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) :1142-1146
[5]   Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype [J].
Catana, Ciprian ;
van der Kouwe, Andre ;
Benner, Thomas ;
Michel, Christian J. ;
Hamm, Michael ;
Fenchel, Matthias ;
Fischl, Bruce ;
Rosen, Bruce ;
Schmand, Matthias ;
Sorensen, A. Gregory .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) :1431-1438
[6]   A Simple Regularizer for B-spline Nonrigid Image Registration That Encourages Local Invertibility [J].
Chun, Se Young ;
Fessler, Jeffrey A. .
IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2009, 3 (01) :159-169
[7]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[8]   First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses [J].
Drzezga, Alexander ;
Souvatzoglou, Michael ;
Eiber, Matthias ;
Beer, Ambros J. ;
Fuerst, Sebastian ;
Martinez-Moeller, Axel ;
Nekolla, Stephan G. ;
Ziegler, Sibylle ;
Ganter, Carl ;
Rummeny, Ernst J. ;
Schwaiger, Markus .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) :845-855
[9]   Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions [J].
Eiber, Matthias ;
Martinez-Moeller, Axel ;
Souvatzoglou, Michael ;
Holzapfel, Konstantin ;
Pickhard, Anja ;
Loeffelbein, Dennys ;
Santi, Ivan ;
Rummeny, Ernst J. ;
Ziegler, Sibylle ;
Schwaiger, Markus ;
Nekolla, Stephan G. ;
Beer, Ambros J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (09) :1691-1701
[10]   MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration [J].
Hofmann, Matthias ;
Steinke, Florian ;
Scheel, Verena ;
Charpiat, Guillaume ;
Farquhar, Jason ;
Aschoff, Philip ;
Brady, Michael ;
Schoelkopf, Bernhard ;
Pichler, Bernd J. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (11) :1875-1883