Determination of uranium-235, uranium-238 and thorium-232 in urine by magnetic sector inductively coupled plasma mass spectrometry

被引:33
作者
Pappas, RS [1 ]
Ting, BG [1 ]
Jarrett, JM [1 ]
Paschal, DC [1 ]
Caudill, SP [1 ]
Miller, DT [1 ]
机构
[1] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
关键词
D O I
10.1039/b108414c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inductively coupled plasma mass spectrometry (ICP-MS) is a very useful method for the determination of long-lived isotopes of uranium, thorium and other elements. This study investigates parameters for measurement of isotopes of these elements in human urine using a magnetic sector ICP-MS method and a previously established quadrupole ICP-MS method. The investigation was performed by means of comparison of data from the determination of U-238, U-235 and Th-232 in urine-based quality control materials, as well as specimens from an investigation of occupational exposure to smoke and particulates from a population of firefighters. In addition to difference in instrumentation, additional isotopes were quantitated, and sample size was decreased to 100 muL for the magnetic sector method from 500 mL for the quadrupole method. Though non-instrumental bias in samples >500 ng L-1 U-238 due to differences in the serial dilution technique (Digiflex diluter for quadrupole, Eppendorf pipettor for the magnetic sector method) was noted, results of comparison of the analyses of samples by magnetic sector ICP-MS compare very favorably with those from quadrupole ICP-MS (rsquared = 0.991 inclusive, 0.987 excluding serially diluted samples), with a near unity slope (0.934 inclusive, 1.06 excluding serially diluted samples) and near-zero intercept (0.0105 inclusive, 0.001 excluding serially diluted samples). Addition of calibration with U-235 (0.72% in NIST U standard) allowed the characterization of QCs and measurement of this isotope using the magnetic sector method with a multi-run (n = 28) urine LOD of 0.06 ng L-1. Other magnetic sector urinary isotopic multi-run LODs were in the below 3 ng L-1 range for a 100 muL sample versus 4 ng L-1 for a 500 muL sample with the quadrupole (n = 43).
引用
收藏
页码:131 / 134
页数:4
相关论文
共 15 条
[1]   ESTIMATING THE CONCENTRATION OF URANIUM IN SOME ENVIRONMENTAL-SAMPLES IN KUWAIT AFTER THE 1991 GULF-WAR [J].
BOURABEE, F .
APPLIED RADIATION AND ISOTOPES, 1995, 46 (04) :217-220
[2]  
DATE A.R., 1989, APPL ICP MS
[3]   Determination of the isotopic composition of uranium in urine by inductively coupled plasma mass spectrometry [J].
Ejnik, JW ;
Carmichael, AJ ;
Hamilton, MM ;
McDiarmid, M ;
Squibb, K ;
Boyd, P ;
Tardiff, W .
HEALTH PHYSICS, 2000, 78 (02) :143-146
[4]  
EZZATI TM, 1992, VITAL HLTH STAT 2, V113
[5]  
GLADNEY ES, 1989, HEALTH PHYS, V57, P171
[6]  
*HLTH PHYS SOC, 1995, N13221995 HPS
[7]   Flow injection method for determination of uranium in urine and serum by inductively coupled plasma mass spectrometry [J].
Lorber, A ;
Karpas, Z ;
Halicz, L .
ANALYTICA CHIMICA ACTA, 1996, 334 (03) :295-301
[8]  
MACLELLAN JA, 1998, RAD PROT MANAGE, V15, P46
[9]  
MACTAGGART DL, 1992, J AOAC INT, V75, P608
[10]   Determination of trace and ultratrace elements in human serum with a double focusing magnetic sector inductively coupled plasma mass spectrometer [J].
Riondato, J ;
Vanhaecke, F ;
Moens, L ;
Dams, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :933-937