Conducted and radiated interference measurements in the line-pantograph system

被引:51
作者
Tellini, B [1 ]
Macucci, M
Giannetti, R
Antonacci, GA
机构
[1] Univ Pisa, Dipartimento Sist Elettr & Automaz, Pisa, Italy
[2] Univ Pisa, Dipartimento Ingn Informaz, Pisa, Italy
[3] Univ Pontificia Comillas Madrid, Dept Elect & Automat, Madrid, Spain
[4] Unita Tecnol Mat Rotabile Sperimentaz, SpA, Florence, Italy
关键词
electromagnetic interference; line-pantograph system; lumped parameter model; time-domain measurements;
D O I
10.1109/19.982964
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the results of a measurement campaign aimed at investigating electromagnetic interference (EMI) phenomena in the interaction between overhead railway power supply lines and pantograph. In order to obtain such data, an experimental setup was assembled in a shielded room, consisting in a short section of overhead line and a full scale pantograph. One of the most interesting results consists in the observation of a very significant (both from the qualitative and the quantitative point of view) difference between the EMI behavior in the switch-on (pantograph going up) and switch-off (pantograph going down) transients.
引用
收藏
页码:1661 / 1664
页数:4
相关论文
共 4 条
[1]  
ANTONACCI GA, 1993, INGEGNERIA FERROVIAR, P320
[2]  
*CENELEC, 1996, 50121 CENELEC
[3]  
*IEC, 1998, CISPRC100CD IEC
[4]  
Tellini B, 1998, IEEE IMTC P, P749, DOI 10.1109/IMTC.1998.676825