On-chip detection of myoglobin based on fluorescence

被引:81
作者
Darain, Farzana [1 ]
Yager, Paul [2 ]
Gan, Kai Ling [1 ]
Tjin, Swee Chuan [3 ]
机构
[1] Nanyang Technol Univ, Biomed Engn Res Ctr, Singapore Univ Washington Alliance, Singapore 639553, Singapore
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[3] Nanyang Technol Univ, Sch Elect & Elect Engn, Photon Res Ctr, Singapore 639798, Singapore
关键词
Cardiac marker; Polystyrene; Surface modification; Microfluidic card; Fluorescence; ACUTE MYOCARDIAL-INFARCTION; DETECTION SYSTEM; IMMUNOASSAY; SURFACE; PROTEIN; ASSAY; POLY(DIMETHYLSILOXANE); IMMOBILIZATION; DIAGNOSIS; MARKERS;
D O I
10.1016/j.bios.2008.09.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A disposable immunosensor cartridge was developed that allows antibodies to be immobilized on the surface for the detection of myoglobin, a marker for the early assessment of acute myocardial infarction (AMI) using fluorescence techniques. The anti-myoglobin antibody was immobilized on a polystyrene substrate based on covalent bonding via silanization. The immunosensor chip layers were fabricated from sheets by CO2-laser ablation. The functionalized polystyrene surfaces were characterized by contact angle measurement, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). After the antigen-antibody reaction as a sandwich enzyme-linked immunosorbent assay (ELISA) with a horseradish peroxidase-conjugated secondary antibody (HRP-anti-myoglobin), addition of fluorogenic substrate produced a fluorescent dye which was quantified on-chip using fluorescent technique. The immunosensor response was linear for myoglobin concentrations between 20 and 230 ng/ml (r=0.991, n = 3). The detection limit was found to be 16 ng/ml, which is lower than the clinical cut-off value for myoglobin in healthy patients. This protocol could be extended to the detection of other important cardiac markers simultaneously in microchannels. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1744 / 1750
页数:7
相关论文
共 38 条
  • [1] Adams J E 3rd, 1998, Am J Crit Care, V7, P418
  • [2] [Anonymous], 1992, HIGH RESOLUTION XPS, DOI DOI 10.1002/ADMA.19930051035
  • [3] Microfluidic immunosensor systems
    Bange, A
    Halsall, HB
    Heineman, WR
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) : 2488 - 2503
  • [4] EVALUATION OF A NEW RAPID QUANTITATIVE IMMUNOASSAY FOR SERUM MYOGLOBIN VERSUS CK-MB FOR RULING OUT ACUTE MYOCARDIAL-INFARCTION IN THE EMERGENCY DEPARTMENT
    BROGAN, GX
    FRIEDMAN, S
    MCCUSKEY, C
    COOLING, DS
    BERRUTTI, L
    THODE, HC
    BOCK, JL
    [J]. ANNALS OF EMERGENCY MEDICINE, 1994, 24 (04) : 665 - 671
  • [5] An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications
    Chabinyc, ML
    Chiu, DT
    McDonald, JC
    Stroock, AD
    Christian, JF
    Karger, AM
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (18) : 4491 - 4498
  • [6] Early diagnosis of acute myocardial infarction using immunosensors and immunotests
    Chan, CPY
    Cheng, WS
    Glatz, JFC
    van der Voort, D
    Sanderson, JE
    Hempel, A
    Lehmann, M
    Renneberg, I
    Renneberg, R
    [J]. ANALYTICAL LETTERS, 2003, 36 (09) : 1987 - 2004
  • [7] Christenson RH, 1998, CLIN CHEM, V44, P1855
  • [8] Plastic fantastic?
    de Mello, A
    [J]. LAB ON A CHIP, 2002, 2 (02) : 31N - 36N
  • [9] Diamandis E.P., 1996, IMMUNOASSAY
  • [10] Egan J. P, 1975, SIGNAL DETECTION THE, P277