Relative importance of errors in left ventricular quantitation by two-dimensional echocardiography: Insights from three-dimensional echocardiography and cardiac magnetic resonance imaging

被引:86
作者
Chukwu, Ebere O. [1 ]
Barasch, Eddy [1 ]
Mihalatos, Dennis G. [1 ]
Katz, Alan [1 ]
Lachmann, Justine [1 ]
Han, Jing [1 ]
Reichek, Nathaniel [1 ]
Gopal, Aasha S. [1 ]
机构
[1] SUNY Stony Brook, St Francis Hosp, Roslyn, NY 11576 USA
关键词
echocardiography; magnetic resonance imaging; myocardial infarction;
D O I
10.1016/j.echo.2008.07.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The accuracy of left ventricular (LV) volumes and ejection fraction (EF) on two-dimensional echocardiography (2DE) is limited by image position (IP), geometric assumption (GA), and boundary tracing (BT) errors. Methods: Real-time three-dimensional echocardiography (RT3DE) and cardiac magnetic resonance imaging (CMR) were used to determine the relative contribution of each error source in normal controls (n = 35) and patients with myocardial infarctions (MIs) (n = 34). LV volumes and EFs were calculated using (1) apical biplane disk summation on 2DE (IP + GA + BT errors), (2) biplane disk summation on RT3DE (GA + BT errors), (3) 4-multiplane to 8-multiplane surface approximation on RT3DE (GA + BT errors), (4) voxel-based surface approximation on RT3DE (BT error alone) and (5) CMR. By comparing each method with CMR, the absolute and relative contributions of each error source were determined. Results: IP error predominated in LV volume quantification on 2DE in normal controls, whereas GA error predominated in patients with MIs. Underestimation of volumes on 2DE was overcome by increasing the number of imaging planes on RT3DE. Although 4 equidistant image planes were acceptable, the best results were achieved with voxel-based RT3DE. For EF estimation, IP error predominated in normal controls, whereas BT error predominated in patients with MIs. Nevertheless, one third of the EF estimation error in patients with MIs was due to a combination of IP and GA errors, both of which may be addressed using RT3DE. Conclusions: The relative contribution of each source of LV quantitation error on 2DE was defined and quantified. Each source of error differed depending on patient characteristics and LV geometry.
引用
收藏
页码:990 / 997
页数:8
相关论文
共 25 条
[1]   Accuracy of measurement of left ventricular volume and election fraction by now real-time three-dimensional echocardiography in patients with wall motion abnormalities secondary to myocardial infarction [J].
Arai, K ;
Hozumi, T ;
Matsumura, Y ;
Sugioka, K ;
Takemoto, Y ;
Yamagishi, H ;
Yoshiyama, M ;
Kasanuki, H ;
Yoshikawa, J .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (05) :552-558
[2]  
Buck T, 1996, J Am Soc Echocardiogr, V9, P488, DOI 10.1016/S0894-7317(96)90120-0
[3]   Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: Comparison with magnetic resonance imaging [J].
Caiani, EG ;
Corsi, C ;
Zamorano, J ;
Sugeng, L ;
MacEneaney, P ;
Weinert, L ;
Battani, R ;
Gutierrez, JL ;
Koch, R ;
de Isla, LP ;
Mor-Avi, V ;
Lang, RM .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (08) :779-788
[4]   What is the optimal clinical technique for measurement of left ventricular volume after myocardial infarction? A comparative study of 3-dimensional echocardiography, single photon emission computed tomography, and cardiac magnetic resonance imaging [J].
Chan, J ;
Jenkins, C ;
Khafagi, F ;
Du, L ;
Marwick, TH .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (02) :192-201
[5]   Relation between the number of image planes and the accuracy of three-dimensional echocardiography for measuring left ventricular volumes and ejection fraction [J].
Danias, PG ;
Chuang, ML ;
Parker, RA ;
Beaudin, RA ;
Mooney, MG ;
Manning, WJ ;
Douglas, PS ;
Hibberd, MG .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (11) :1431-+
[6]   ECHOCARDIOGRAPHIC DETERMINATION OF LEFT-VENTRICULAR MASS IN MAN - ANATOMIC VALIDATION OF METHOD [J].
DEVEREUX, RB ;
REICHEK, N .
CIRCULATION, 1977, 55 (04) :613-618
[7]   ECHOVENTRICULOGRAPHY - A SIMULTANEOUS ANALYSIS OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND CINEVENTRICULOGRAPHY [J].
ERBEL, R ;
SCHWEIZER, P ;
LAMBERTZ, H ;
HENN, G ;
MEYER, J ;
KREBS, W ;
EFFERT, S .
CIRCULATION, 1983, 67 (01) :205-215
[8]   ASSESSMENT OF CARDIAC-FUNCTION BY 3-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH CONVENTIONAL NONINVASIVE METHODS [J].
GOPAL, AS ;
SHEN, ZQ ;
SAPIN, PM ;
KELLER, AM ;
SCHNELLBAECHER, MJ ;
LEIBOWITZ, DW ;
AKINBOBOYE, OO ;
RODNEY, RA ;
BLOOD, DK ;
KING, DL .
CIRCULATION, 1995, 92 (04) :842-853
[9]   Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies [J].
Gutiérrez-Chico, JL ;
Zamorano, JL ;
de Isla, LP ;
Orejas, M ;
Almería, C ;
Rodrigo, JL ;
Ferreirós, J ;
Serra, V ;
Macaya, C .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (06) :809-813
[10]   Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction [J].
Hibberd, MG ;
Chuang, ML ;
Beaudin, RA ;
Riley, MF ;
Mooney, MG ;
Fearnside, JT ;
Manning, WJ ;
Douglas, PS .
AMERICAN HEART JOURNAL, 2000, 140 (03) :469-475