Swallowing, arterial pulsation, and breathing induce motion artifacts in carotid artery MRI

被引:51
作者
Boussel, L
Herigault, G
de la Vega, A
Nonent, M
Douek, PC
Serfaty, JM
机构
[1] Univ Hosp Ctr, Dept Radiol, Lyon, France
[2] Philips Med Syst, Suresnes, France
[3] Xavier Bichat Univ, Dept Radiol, Paris, France
关键词
carotid stenosis; magnetic resonance angiography; atherosclerosis; atherosclerotic plaque; carotid motion;
D O I
10.1002/jmri.20525
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To identify and quantify the potential sources of motion in carotid artery imaging. Materials and Methods: Two healthy volunteers and 12 patients (20-75 years old) with atherosclerotic disease were scanned on a Philips Intera 1.5T system. A single-shot balanced-fast field echo (bFFE) sequence was used to acquire real-time axial views of the carotid artery wall (three images per second). A three-step acquisition protocol was performed to analyze the three types of motion (arterial pulsation, breathing, and swallowing) separately. The isocenter carotid artery motion amplitude in either the x or y direction was measured. Radial variation in the carotid lumen between the systolic and diastolic phases was analyzed. Motion frequency was reported for each patient. Results: Significant motion related to arterial pulsation (amplitude = 0.27-0.93 mm, mean = 0.6, SD = 0.19), breathing (amplitude = 0.5-3.6 mm, mean = 1.56, SD = 0.99)), and swallowing (amplitude = 1.4-9.2 mm, mean = 4.7, SD = 2.4) were visualized. Conclusion: Pulsation, breathing, and swallowing are sources of significant motion in the carotid artery wall. Such motion should be considered in the future to improve carotid artery image quality.
引用
收藏
页码:413 / 415
页数:3
相关论文
共 8 条
[1]   Pulsatile motion effects on 3D magnetic resonance angiography: Implications for evaluating carotid artery stenoses [J].
Al-Kwifi, O ;
Kim, JK ;
Stainsby, J ;
Huang, YX ;
Sussman, MS ;
Farb, RI ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) :605-611
[2]   Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European carotid surgery trial (ECST) [J].
Farrell, B ;
Fraser, A ;
Sandercock, P ;
Slattery, J ;
Warlow, CP .
LANCET, 1998, 351 (9113) :1379-1387
[3]   Carotid artery wall motion estimated from B-mode ultrasound using region tracking and block matching [J].
Golemati, S ;
Sassano, A ;
Lever, MJ ;
Bharath, AA ;
Dhanjil, S ;
Nicolaides, AN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03) :387-399
[4]   Noise and motion correction in dynamic contrast-enhanced MRI for analysis of atherosclerotic lesions [J].
Kerwin, WS ;
Cai, J ;
Yuan, C .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1211-1217
[5]   Concordance rate differences of 3 noninvasive imaging techniques to measure carotid stenosis in clinical routine practice - Results of the CARMEDAS Multicenter Study [J].
Nonent, M ;
Serfaty, JM ;
Nighoghossian, N ;
Rouhart, F ;
Derex, L ;
Rotaru, C ;
Chirossel, P ;
Guias, B ;
Heautot, JF ;
Gouny, P ;
Langella, B ;
Buthion, V ;
Jars, I ;
Pachai, C ;
Veyret, C ;
Gauvrit, JY ;
Lamure, M ;
Douek, PC .
STROKE, 2004, 35 (03) :682-686
[6]   Factors underlying the increase in carotid intima-media thickness in borderline hypertensives [J].
Pauletto, P ;
Palatini, P ;
Da Ros, S ;
Pagliara, V ;
Santipolo, N ;
Baccillieri, S ;
Casiglia, E ;
Mormino, P ;
Pessina, AC .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1999, 19 (05) :1231-1237
[7]   Accuracy of three-dimensional gadolinium-enhanced MR angiography in the assessment of extracranial carotid artery disease [J].
Serfaty, JM ;
Chirossel, P ;
Chevallier, JM ;
Ecochard, R ;
Froment, JC ;
Douek, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :455-463
[8]   Identification of fibrous cap rupture with magnetic resonance imaging is highly associated with recent transient ischemic attack or stroke [J].
Yuan, C ;
Zhang, SX ;
Polissar, NL ;
Echelard, D ;
Ortiz, G ;
Davis, JW ;
Ellington, E ;
Ferguson, MS ;
Hatsukami, TS .
CIRCULATION, 2002, 105 (02) :181-185