Comparison and evaluation of retrospective intermodality brain image registration techniques

被引:655
作者
West, J
Fitzpatrick, JM
Wang, MY
Dawant, BM
Maurer, CR
Kessler, RM
Maciunas, RJ
Barillot, C
Lemoine, D
Collignon, A
Maes, F
Suetens, P
Vandermeulen, D
vandenElsen, PA
Napel, S
Sumanaweera, TS
Harkness, B
Hemler, PF
Hill, DLG
Hawkes, DJ
Studholme, C
Maintz, JBA
Viergever, MA
Malandain, G
Pennec, X
Noz, ME
Maguire, GQ
Pollack, M
Pelizzari, CA
Robb, RA
Hanson, D
Woods, RP
机构
[1] VANDERBILT UNIV, DEPT COMP SCI, NASHVILLE, TN 37235 USA
[2] VANDERBILT UNIV, DEPT ELECT ENGN, NASHVILLE, TN 37235 USA
[3] VANDERBILT UNIV, DEPT BIOMED ENGN, NASHVILLE, TN 37235 USA
[4] VANDERBILT UNIV, DEPT RADIOL, NASHVILLE, TN 37235 USA
[5] VANDERBILT UNIV, DEPT NEUROL SURG, NASHVILLE, TN 37235 USA
[6] STANFORD UNIV, MED CTR, STANFORD, CA 94305 USA
[7] UNIV CALIF LOS ANGELES, SCH MED, LOS ANGELES, CA 90024 USA
[8] WAKE FOREST UNIV, BOWMAN GRAY SCH MED, WINSTON SALEM, NC USA
[9] NYU, MED CTR, NEW YORK, NY 10016 USA
[10] UNIV CHICAGO HOSP, CHICAGO, IL 60637 USA
[11] MAYO CLIN, ROCHESTER, MN USA
[12] UNIV RENNES, RENNES, FRANCE
[13] INRIA, SOPHIA ANTIPOLIS, FRANCE
[14] KATHOLIEKE UNIV LEUVEN, B-3001 LOUVAIN, BELGIUM
[15] UMDS, GUYS & ST THOMAS HOSP, LONDON, ENGLAND
[16] UNIV UTRECHT HOSP, UTRECHT, NETHERLANDS
关键词
image registration; computed tomography; magnetic resonance imaging; emission computed tomography; image quality; physics and instrumentation;
D O I
10.1097/00004728-199707000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The primary objective of this study is to perform a blinded evaluation of a group of retrospective image registration techniques using as a gold standard a prospective, marker-based registration method. To ensure blindedness, all retrospective registrations were performed by participants who had no knowledge of the gold standard results until after their results had been submitted. A secondary goal of the project is to evaluate the importance of correcting geometrical distortion in MR images by comparing the retrospective registration error in the rectified images, i.e., those that have had the distortion correction applied, with that of the same images before rectification. Method: Image volumes of three modalities (CT, MR, and PET) were obtained from patients undergoing neurosurgery at Vanderbilt University Medical Center on whom bone-implanted fiducial markers were mounted. These volumes had all traces of the markers removed and were provided via the Internet to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/or from PET to MR. These investigators communicated their transformations again via the Internet to Vanderbilt, where the accuracy bf each registration was evaluated. In this evaluation, the accuracy is measured at multiple volumes of interest (VOIs), i.e., areas in the brain that would commonly be areas of neurological interest. A VOI is defined in the MR image and its centroid c is determined. Then, the prospective registration is used to obtain the corresponding point c' in CT or PET. To this point, the retrospective registration is then applied, producing c '' in MR. Statistics are gathered on the target registration error (TRE), which is the distance between the original point c and its corresponding point c ''. Results: This article presents statistics on the TRE calculated for each registration technique in this study and provides a brief description of each technique and an estimate of both preparation and execution time needed to perform the registration. Conclusion: Our results indicate that retrospective techniques have the potential to produce satisfactory results much of the time, but that visual inspection is necessary to guard against large errors.
引用
收藏
页码:554 / 566
页数:13
相关论文
共 32 条
[1]  
[Anonymous], 1994, P VBC
[2]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[3]  
Baxter BS, 1982, STANDARD FORMAT DIGI
[4]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[5]  
COLLIGNON A, 1995, COMP IMAG VIS, V3, P263
[6]   A STANDARD PROTOCOL FOR THE EXCHANGE OF NUCLEAR-MEDICINE IMAGE FILES [J].
CRADDUCK, TD ;
BAILEY, DL ;
HUTTON, BF ;
DECONNINCK, F ;
BUSEMANNSOKOLE, E ;
BERGMANN, H ;
NOELPP, U .
NUCLEAR MEDICINE COMMUNICATIONS, 1989, 10 (10) :703-713
[7]  
Hemler P F, 1995, J Image Guid Surg, V1, P35, DOI 10.1002/(SICI)1522-712X(1995)1:1<35::AID-IGS6>3.0.CO
[8]  
2-N
[9]  
Hill D. L. G., 1993, Information Processing in Medical Imaging. 13th International Conference, IPMI '93 Proceedings, P182, DOI 10.1007/BFb0013788
[10]  
JIANG HJ, 1992, P SOC PHOTO-OPT INS, V1660, P356, DOI 10.1117/12.59565