Doppler echocardiography in the dog: Measurement variability and reproducibility

被引:50
作者
Dukes-McEwan, J [1 ]
French, AT [1 ]
Corcoran, BM [1 ]
机构
[1] Univ Edinburgh, Easter Bush Vet Ctr, Royal Dick Sch Vet Studies,Dept Vet Clin Studies, Hosp Small Anim,Cardiopulm Serv, Roslin EH25 9RG, Midlothian, Scotland
关键词
echocardiography; boxer dogs; doppler; screening for heart disease; repeatability;
D O I
10.1111/j.1740-8261.2002.tb01662.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Serial Doppler echocardiographic examinations were carried out in random order on sit boxer dogs, on 3 separate days, by two experienced Doppler echocardiographers, to assess measurement variability and reproducibility of 65 parameters. Large numbers of parameters exhibited significant differences for each of the categories of intraobserver, interobserver, interday and interoperator. The coefficients of variation for all parameters measured ranged from 5.03 to 46.43%, but most were less than 20 c. In general, least variation was found for the intraobserver category, and the best reproducibility for I-mode and left ventricular volumetric data. The worst reproducibility was found for tricuspid inflow and pulmonary venous flow measurements. The results of this study suggest differences greater than 20% for serial scans must be achieved to document genuine change, although the specific data should be consulted. Furthermore, variability and reproducibility are improved if a single experienced operator/observer acquires and measures serial scans.
引用
收藏
页码:144 / 152
页数:9
相关论文
共 19 条
[1]   Doppler evaluation of left and right ventricular diastolic function: A technical guide for obtaining optimal flow velocity recordings [J].
Appleton, CP ;
Jensen, JL ;
Hatle, LK ;
Oh, JK .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (03) :271-292
[2]  
BORGARELLI M, 2000, P 18 AM COLL VET INT, P78
[3]   PEAK FILLING RATE NORMALIZED TO MITRAL STROKE VOLUME - A NEW DOPPLER ECHOCARDIOGRAPHIC FILLING INDEX VALIDATED BY RADIONUCLIDE ANGIOGRAPHIC TECHNIQUES [J].
BOWMAN, LK ;
LEE, FA ;
JAFFE, CC ;
MATTERA, J ;
WACKERS, FJT ;
ZARET, BL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (04) :937-943
[4]  
Feigenbaum H., 1994, ECHOCARDIOGR-J CARD, P68
[5]   EFFECT OF IMAGING VIEW AND SAMPLE VOLUME LOCATION ON EVALUATION OF MITRAL FLOW VELOCITY BY PULSED DOPPLER ECHOCARDIOGRAPHY [J].
GARDIN, JM ;
DABESTANI, A ;
TAKENAKA, K ;
ROHAN, MK ;
KNOLL, M ;
RUSSELL, D ;
HENRY, WL .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (15) :1335-1339
[6]  
Gentile F, 1997, EUR HEART J, V18, P148
[7]  
Herrtage M E., 1994, Proc Eur Soc Vet Intern Med 4th Annu Congress, Brussels, Belgium, P172
[8]  
Kuecherer H F, 1991, J Am Soc Echocardiogr, V4, P203
[9]  
LEHMKUHL LB, 1994, AM J VET RES, V55, P192
[10]  
Moise NS, 1999, TXB CANINE FELINE CA, P130