Transient model for induction machines with stator winding turn faults

被引:276
作者
Tallam, RM [1 ]
Habetler, TG [1 ]
Harley, RG [1 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
关键词
fault diagnostics; induction machine transient model; negative sequence; stator winding turn fault;
D O I
10.1109/TIA.2002.1003411
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A transient model for an induction machine with stator winding turn faults is derived using reference frame transformation theory. A state-space representation of the dynamic equations, suitable for digital simulation is provided. Steady-state equivalent circuits are derived, from which the sequence components of the line currents can be estimated as a function of fault severity. Experimental results are provided to validate the derived model.