Thin-section multidetector CT angiography of renal artery stents

被引:35
作者
Behar, JV
Nelson, RC
Zidar, JP
DeLong, DM
Smith, TP
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Med, Durham, NC 27710 USA
关键词
D O I
10.2214/ajr.178.5.1781155
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study was undertaken as a pilot investigation to compare multidetector CT angiography with conventional catheter angiography for the visualization of the renal artery lumen after renal artery stent placement. SUBJECTS AND METHODS. CT angiography was performed within 24-48 hr of renal artery stent placement in 15 patients. Two patients had bilateral stents, resulting in a total of 17 stents. CT angiography was performed using a multidetector scanner and a bolus of IV contrast material with the scanning delay determined by a small-volume timing bolus. A volumetric data set was acquired through the stented arteries in the axial plane using a 4.0 x 1.25 mm detector configuration and a pitch of 3:1. The stent lumen diameter, as measured on direct CT angiography and curved multiplanar reformations in both the axial and coronal planes, was compared with that measured on catheter angiography. RESULTS. The lumina of all 17 stents were well visualized and patent on both CT angiography and catheter angiography. Anatomic definition, including stent position and wall apposition in the renal artery, correlated well with catheter angiography. The diameter of the renal artery stent lumen measured on catheter angiography (mean, 5.9 +/- 1.3 mm) was greater than that on CT angiography (mean stent lumen diameter for direct axial plane was 4.6 +/- 1.0 mm, for curved multiplanar reformations in the axial plane was 4.3 +/- 1.0 mm, and for curved multiplanar reformations in the coronal plane was 4.4 +/- 1.0 mm) in 14 (82%) of 17 stents. CONCLUSION. CT angiography produced interpretable multiplanar images of the renal artery, even with a metallic stent in place, and was adequate for determining stent patency. Compared with catheter angiography, the intrastent luminal diameter was underestimated in most patients who underwent CT angiography.
引用
收藏
页码:1155 / 1159
页数:5
相关论文
共 20 条
[1]   Stent placement in ostial and nonostial atherosclerotic renal arterial stenoses: A prospective follow-up study [J].
Baumgartner, I ;
von Aesch, K ;
Do, DD ;
Triller, J ;
Birrer, M ;
Mahler, F .
RADIOLOGY, 2000, 216 (02) :498-505
[2]   Helical CT angiography compared with arteriography in the detection of renal artery stenosis [J].
Beregi, JP ;
Elkohen, M ;
Deklunder, G ;
Artaud, D ;
Coullet, JM ;
Wattinne, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :495-501
[3]   Treatment of renal angioplasty failure by percutaneous renal artery stenting with Palmaz stents: Midterm technical and clinical results [J].
Boisclair, C ;
Therasse, E ;
Oliva, VL ;
Soulez, G ;
Bui, BT ;
Querin, S ;
Robillard, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (01) :245-251
[4]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[5]   Renal artery stenosis: Evaluation with conventional angiography versus gadolinium-enhanced MR angiography [J].
Gilfeather, M ;
Yoon, HC ;
Siegelman, ES ;
Axel, L ;
Stolpen, AH ;
Shlansky-Goldberg, RD ;
Baum, RA ;
Soulen, MC ;
Schnall, MD .
RADIOLOGY, 1999, 210 (02) :367-372
[6]  
Henry M, 1999, J ENDOVASC SURG, V6, P42, DOI 10.1583/1074-6218(1999)006<0042:SITTOR>2.0.CO
[7]  
2
[8]   Ostial renal artery stenosis angioplasty: Immediate and mid-term angiographic and clinical results [J].
Hoffman, O ;
Carreres, T ;
Sapoval, MR ;
Auguste, MC ;
Beyssen, BM ;
Raynaud, AC ;
Gaux, JC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (01) :65-73
[9]   Renal artery evaluation: Comparison of spiral CT angiography to intra-arterial DSA [J].
Kim, TS ;
Chung, JW ;
Park, JH ;
Kim, SH ;
Yeon, KM ;
Han, MC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (04) :553-559
[10]   MAGNETIC-RESONANCE ANGIOGRAPHY OF INTRAVASCULAR ENDOPROSTHESES - INVESTIGATION OF 3 DEVICES [J].
LAISSY, JP ;
GRAND, C ;
MATOS, C ;
STRUYVEN, J ;
BERGER, JF ;
SCHOUMANCLAEYS, E .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 18 (06) :360-366