How Active Are People With Stroke? Use of Accelerometers to Assess Physical Activity

被引:238
作者
Rand, Debbie [1 ,2 ,7 ]
Eng, Janice J. [1 ,2 ,7 ]
Tang, Pei-Fang [3 ,4 ,5 ]
Jeng, Jiann-Shing [6 ]
Hung, Chihya [1 ,2 ]
机构
[1] Univ British Columbia, Dept Phys Therapy, Vancouver, BC V6T 2B5, Canada
[2] GF Strong Rehab Ctr, Rehab Res Lab, Vancouver, BC, Canada
[3] Natl Taiwan Univ, Coll Med, Sch & Grad Inst Phys Therapy, Taipei 10764, Taiwan
[4] Natl Taiwan Univ Hosp, Phys Therapy Ctr, Taipei, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Phys Med & Rehabil, Taipei, Taiwan
[6] Natl Taiwan Univ Hosp, Dept Neurol, Taipei, Taiwan
[7] Int Collaborat Repair Discoveries, Vancouver, BC, Canada
关键词
accelerometers; community-dwelling; physical activity; stroke; 6-MINUTE WALK TEST; ACTIVITY MONITORS; RELIABILITY; ADULTS; REHABILITATION; PERFORMANCE; VALIDITY; HEALTH; TESTS; INDIVIDUALS;
D O I
10.1161/STROKEAHA.108.523621
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Accelerometers are a unique tool used to objectively measure free-living physical activity, but their reliability for people with stroke has not been established. The primary aim was to assess the day-to-day reliability of these instruments for the paretic and nonparetic hips. The secondary aims were to measure the amount of physical activity with accelerometers that people with stroke undertake in the community and its relationship with walking capacity (6-minute walk test distance). Methods-Forty people with stroke wore one Actical accelerometer on each hip for 3 consecutive days at home and during the 6-minute walk test in the laboratory. The accelerometer measured physical activity using total activity counts per day and energy expenditure (kcal/d). Results-Excellent intraclass correlation coefficients (ICCs) for the activity counts (paretic hip ICC[1,3] = 0.95, nonparetic hip ICC[1,3] = 0.94) and for the energy expenditure (paretic hip ICC[1,3] = 0.95, nonparetic hip ICC[1,3] = 0.95) were found across the 3 consecutive days at home. Excellent ICCs were also found between the paretic versus the nonparetic hips for the activity counts (ICC[1,3] = 0.98) and for the energy expenditure (ICC[1,3] = 0.96). Free-living physical activity was very low and 58% of the participants did not meet recommended physical activity levels. Only moderate correlations (r = 0.6 to 0.73, P < 0.001) were found between the 6-minute walk test distance in the laboratory and 3-day physical activity recording at home. Conclusions-The accelerometer was found to be a reliable objective instrument. The use of accelerometers quantified the low level of free-living physical activity of people with stroke. (Stroke. 2009; 40: 163-168.)
引用
收藏
页码:163 / 168
页数:6
相关论文
共 42 条
  • [1] STROKE RECOVERY - HE CAN BUT DOES HE
    ANDREWS, K
    STEWART, J
    [J]. RHEUMATOLOGY AND REHABILITATION, 1979, 18 (01): : 43 - 48
  • [2] Bohannon RW, 2007, TOP GERIATR REHABIL, V23, P155
  • [3] Maximal grip force in chronic stroke subjects and its relationship to global upper extremity function
    Boissy, P
    Bourbonnais, D
    Carlotti, MM
    Gravel, D
    Arsenault, BA
    [J]. CLINICAL REHABILITATION, 1999, 13 (04) : 354 - 362
  • [4] ATS statement: Guidelines for the six-minute walk test
    Crapo, RO
    Casaburi, R
    Coates, AL
    Enright, PL
    MacIntyre, NR
    McKay, RT
    Johnson, D
    Wanger, JS
    Zeballos, RJ
    Bittner, V
    Mottram, C
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (01) : 111 - 117
  • [5] Functional walk tests in individuals with stroke - Relation to perceived exertion and myocardial exertion
    Eng, JJ
    Chu, KS
    Dawson, AS
    Kim, CM
    Hepburn, KE
    [J]. STROKE, 2002, 33 (03) : 756 - 761
  • [6] Validity of the actical accelerometer step-count function
    Esliger, Dale W.
    Probert, Adam
    Gorber, Sarah Connor
    Bryan, Shirley
    Laviolette, Manon
    Tremblay, Mark S.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (07) : 1200 - 1204
  • [7] Technical reliability assessment of three accelerometer models in a mechanical setup
    Esliger, Dale W.
    Tremblay, Mark S.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (12) : 2173 - 2181
  • [8] Reliability of gait performance tests in men and women with hemiparesis after stroke
    Flansbjer, UB
    Holmbäck, AM
    Downham, D
    Patten, C
    Lexell, J
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2005, 37 (02) : 75 - 82
  • [9] EQUIVALENCE OF WEIGHTED KAPPA AND INTRACLASS CORRELATION COEFFICIENT AS MEASURES OF RELIABILITY
    FLEISS, JL
    COHEN, J
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1973, 33 (03) : 613 - 619
  • [10] Fleiss JL., 1986, DESIGN ANAL CLIN EXP