A comparison of the Invos 3100 and the Critikon 2020 near-infrared spectrophotometers as monitors of cerebral oxygenation

被引:31
作者
McKeating, EG
Monjardino, JR
Signorini, DF
Souter, MJ
Andrews, PJD
机构
[1] Department of Anaesthetics, University of Edinburgh, Western General Hospital
关键词
equipment; near-infrared spectrophotometer; brain; oxygenation;
D O I
10.1111/j.1365-2044.1997.18-az015.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Assessment of cerebral oxygenation using near-infrared spectroscopy in intensive care is increasing. We compared the ability of the Invos 3100 and the Critikon 2020 monitors to produce stable and consistent readings of regional cerebral oxygen saturation in resting volunteers. Failure to obtain any stable reading with the Critikon occurred in eight out of 18 subjects (44.4%) and with the Invos in three out of 15 subjects (20%). The Critikon showed a significantly higher failure rate in male subjects (p = 0.0011). Differences in recorded values of cerebral oxygen saturation (Critikon - Invos) ranged from -4.7% to 12.6% and were significantly related to the average saturation level (p < 0.0001). The within-monitor variability was significantly higher for the Invos (p = 0.0124). Neither monitor is able to give stable and consistent readings over time, particularly in male subjects. The unacceptably high failure rate of the recently introduced Critikon 2020 will limit or prevent its clinical use.
引用
收藏
页码:136 / 140
页数:5
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BRAZY JE, 1985, PEDIATRICS, V75, P217
[3]   A COMPARATIVE-STUDY OF 2 NEAR-INFRARED SPECTROPHOTOMETERS FOR THE ASSESSMENT OF CEREBRAL HEMODYNAMICS [J].
COLIER, WNJM ;
VANHAAREN, NJCW ;
OESEBURG, B .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 :101-105
[4]  
DELPY DT, 1987, SCAND J CLIN LAB INV, V47, P9
[5]  
DUJOVNY M, 1994, NEUROSURGERY, V34, P935
[6]   CEREBRAL OXIMETRY - A USEFUL MONITOR DURING CAROTID-ARTERY SURGERY [J].
DUNCAN, LA ;
RUCKLEY, CV ;
WILDSMITH, JAW .
ANAESTHESIA, 1995, 50 (12) :1041-1045
[7]   SOMANETICS INVOS-3100 CEREBRAL OXIMETER [J].
GOPINATH, SP .
NEUROSURGERY, 1994, 35 (04) :796-796
[8]   NEAR-INFRARED SPECTROSCOPY [J].
HARRIS, DNF .
ANAESTHESIA, 1995, 50 (12) :1015-1016
[9]   NEAR-INFRARED SPECTROSCOPY IN ADULTS - DOES THE INVOS 3100 REALLY MEASURE INTRACEREBRAL OXYGENATION [J].
HARRIS, DNF ;
BAILEY, SM .
ANAESTHESIA, 1993, 48 (08) :694-696
[10]   A MONTE-CARLO INVESTIGATION OF OPTICAL PATHLENGTH IN INHOMOGENEOUS TISSUE AND ITS APPLICATION TO NEAR-INFRARED SPECTROSCOPY [J].
HIRAOKA, M ;
FIRBANK, M ;
ESSENPREIS, M ;
COPE, M ;
ARRIDGE, SR ;
VANDERZEE, P ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (12) :1859-1876