Dynamic physiological modeling for functional diffuse optical tomography

被引:94
作者
Diamond, SG [1 ]
Huppert, TJ
Kolehmainen, V
Franceschini, MA
Kaipio, JP
Arridge, SR
Boas, DA
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
[3] UCL, Dept Comp Sci, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
physiological modeling; state-space model; near-infrared spectroscopy; diffuse optical tomography; Kalman filter; time-series analysis;
D O I
10.1016/j.neuroimage.2005.09.016
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Diffuse optical tomography (DOT) is a noninvasive imaging technology that is sensitive to local concentration changes in oxy- and deoxyhemoglobin. When applied to functional neuroimaging, DOT measures hemodynamics in the scalp and brain that reflect competing metabolic demands and cardiovascular dynamics. The diffuse nature of near-infrared photon migration in tissue and the multitude of physiological systems that affect hemodynamics motivate the use of anatomical and physiological models to improve estimates of the functional hemodynamic response. In this paper, we present a linear state-space model for DOT analysis that models the physiological fluctuations present in the data with either static or dynamic estimation. We demonstrate the approach by using auxiliary measurements of blood pressure variability and heart rate variability as inputs to model the background physiology in DOT data. We evaluate the improvements accorded by modeling this physiology on ten human subjects with simulated functional hemodynamic responses added to the baseline physiology. Adding physiological modeling with a static estimator significantly improved estimates of the simulated functional response, and further significant improvements were achieved with a dynamic Kalman filter estimator (paired t tests, it = 10, P < 0.05). These results suggest that physiological modeling can improve DOT analysis. The further improvement with the Kalman filter encourages continued research into dynamic linear modeling of the physiology present in DOT. Cardiovascular dynamics also affect the blood-oxygen-dependent (BOLD) signal in functional magnetic resonance imaging (fMRI). This state-space approach to DOT analysis could be extended to BOLD fMRI analysis, multimodal studies and real-time analysis. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:88 / 101
页数:14
相关论文
共 105 条
[1]   Noninvasive continuous monitoring of cerebral oxygenation periictally using near-infrared spectroscopy: A preliminary report [J].
Adelson, PD ;
Nemoto, E ;
Scheuer, M ;
Painter, M ;
Morgan, J ;
Yonas, H .
EPILEPSIA, 1999, 40 (11) :1484-1489
[2]  
[Anonymous], 2003, CARDIOVASC ENG, V3, P1
[3]  
[Anonymous], 2004, STAT COMPUTATIONAL I
[4]  
[Anonymous], 2004, CARDIOVASC ENG, DOI DOI 10.1023/B:CARE.0000025123.43747.E1
[5]   Adaptive AR modeling of nonstationary time series by means of Kalman filtering [J].
Arnold, M ;
Miltner, WHR ;
Witte, H ;
Bauer, R ;
Braun, C .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (05) :553-562
[6]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[7]   THE THEORETICAL BASIS FOR THE DETERMINATION OF OPTICAL PATHLENGTHS IN TISSUE - TEMPORAL AND FREQUENCY-ANALYSIS [J].
ARRIDGE, SR ;
COPE, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (07) :1531-1560
[8]   Frontal lobe activation during object permanence: Data from near-infrared spectroscopy [J].
Baird, AA ;
Kagan, J ;
Gaudette, T ;
Walz, KA ;
Hershlag, N ;
Boas, DA .
NEUROIMAGE, 2002, 16 (04) :1120-1126
[9]   MRI-guided optical tomography: Prospects and computation for a new imaging method [J].
Barbour, RL ;
Graber, HL ;
Chang, JW ;
Barbour, SLS ;
Koo, PC ;
Aronson, R .
IEEE COMPUTATIONAL SCIENCE & ENGINEERING, 1995, 2 (04) :63-77
[10]   Three-dimensional optical tomography of hemodynamics in the human head [J].
Bluestone, AY ;
Abdoulaev, G ;
Schmitz, CH ;
Barbour, RL ;
Hielscher, AH .
OPTICS EXPRESS, 2001, 9 (06) :272-286