A method involving the semirobotic liquid-liquid extraction (LLE) in deep-well 96-well plates was developed for the quantitation of the anti-cancer/antiinflammatory drug methotrexate (MTX) and its major metabolite, 7-hydroymethotrexate (70H-MTX) in human plasma. The extraction time for the sample preparation was relatively short with four 96-well plates (384 samples) prepared in approximately 90 min by one person. The sample extracts were each analyzed within 1.2 min using a positive ion turbo-ionspray selected reaction monitoring liquid chromatography/mass spectrometric (SRM LC/MS) method in which 768 samples were easily analyzed within 22 h (maximum of 820 samples in 24 h). Deuterated internal standards, MTX-d(3) and 70H-MTX-d(3), were used. The calibration curves for MTX and 70H-MTX were linear (R-2 > 0.997) and ranged from 0.5 to 250 and 0.75 to 100 ng/mL, respectively. The limit of quantitation (LOQ) for MTX and 70H-MTX was 0.5 and 0.75 ng/mL, respectively; persistent carryover from the autosampler limited the LOQ achievable. The limit of detection (LOD) was 0.05 ng/mL for MTX and 0.1 ng/mL for 70H-MTX The intra- and inter-assay precision and accuracy did not exceed 15% for both MTX and 70H-MTX. The recoveries were 61% for MTX and 47% for 70H-MTX The method was validated and demonstrated to be robust with high precision and accuracy.
引用
收藏
页码:2340 / 2345
页数:6
相关论文
共 30 条
  • [1] SIMULTANEOUS QUANTITATION OF METHOTREXATE AND ITS 2 MAIN METABOLITES IN BIOLOGICAL-FLUIDS BY A NOVEL SOLID-PHASE EXTRACTION PROCEDURE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ALBERTIONI, F
    PETTERSSON, B
    BECK, O
    RASK, C
    SEIDEMAN, P
    PETERSON, C
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 665 (01): : 163 - 170
  • [2] Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
  • [3] 2-Q
  • [4] Anderson MA, 1997, J MASS SPECTROM, V32, P152, DOI 10.1002/(SICI)1096-9888(199702)32:2<152::AID-JMS456>3.0.CO
  • [5] 2-W
  • [6] Beaudry F, 1998, RAPID COMMUN MASS SP, V12, P1216, DOI 10.1002/(SICI)1097-0231(19980915)12:17<1216::AID-RCM304>3.0.CO
  • [7] 2-O
  • [8] BERTINO JR, 1993, CANC MED, V1, P698
  • [9] BLEVINS DD, 1998, LC GC CURRENT TR MAY, pS16
  • [10] Bowers GD, 1997, LC GC-MAG SEP SCI, V15, P48