First astronomical application of a cryogenic transition edge sensor spectrophotometer

被引:54
作者
Romani, RW [1 ]
Miller, AJ
Cabrera, B
Figueroa-Feliciano, E
Nam, SW
机构
[1] Stanford Univ, Dept Phys, Stanford, CA 94305 USA
[2] Natl Inst Stand & Technol, Boulder, CO 80303 USA
基金
美国国家航空航天局;
关键词
instrumentation : detectors pulsars : individual (PSR B0531+21);
D O I
10.1086/312202
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We report on the first astronomical observations with a photon-counting pixel detector that provides arrival time (delta t = 100 ns) and energy (delta E-gamma less than or equal to 0.15 eV) resolved measurements from the near-IR through the near UV. Our test observations were performed by coupling this transition edge sensor device to a 0.6 m telescope; we have obtained the first simultaneous optical near-IR phase-resolved spectra of the Crab pulsar. A varying infrared turnover gives evidence of self-absorption in the pulsar plasma. The potential of such detectors in imaging arrays from a space platform is briefly described.
引用
收藏
页码:L153 / L156
页数:4
相关论文
共 19 条
[1]   Detection of single infrared, optical, and ultraviolet photons using superconducting transition edge sensors [J].
Cabrera, B ;
Clarke, RM ;
Colling, P ;
Miller, AJ ;
Nam, S ;
Romani, RW .
APPLIED PHYSICS LETTERS, 1998, 73 (06) :735-737
[2]   Superconducting multiplexer for arrays of transition edge sensors [J].
Chervenak, JA ;
Irwin, KD ;
Grossman, EN ;
Martinis, JM ;
Reintsema, CD ;
Huber, ME .
APPLIED PHYSICS LETTERS, 1999, 74 (26) :4043-4045
[3]  
Edwards D.F., 1985, Handbook of optical constants of solids
[4]   The infrared to gamma-ray pulse shape of the Crab Nebula pulsar [J].
Eikenberry, SS ;
Fazio, GG .
ASTROPHYSICAL JOURNAL, 1997, 476 (01) :281-290
[5]  
Fioc M, 1997, ASTRON ASTROPHYS, V326, P950
[6]   STELLAR SPECTROPHOTOMETRIC ATLAS, 3130 LESS-THAN LAMBDA LESS-THAN 10800 A [J].
GUNN, JE ;
STRYKER, LL .
ASTROPHYSICAL JOURNAL SUPPLEMENT SERIES, 1983, 52 (02) :121-153
[8]   Analysis of OH absorption bands in synthetic silica [J].
Humbach, O ;
Fabian, H ;
Grzesik, U ;
Haken, U ;
Heitmann, W .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1996, 203 :19-26
[9]   AN APPLICATION OF ELECTROTHERMAL FEEDBACK FOR HIGH-RESOLUTION CRYOGENIC PARTICLE-DETECTION [J].
IRWIN, KD .
APPLIED PHYSICS LETTERS, 1995, 66 (15) :1998-2000
[10]   INFRARED STUDY OF THE CRAB PULSAR - THE SHOULDER PULSE AND THE 3.45 MICRON PULSE PROFILE [J].
MIDDLEDITCH, J ;
PENNYPACKER, C ;
BURNS, MS .
ASTROPHYSICAL JOURNAL, 1983, 273 (01) :261-266