Experimental evaluation of a cell module for hybrid liver support

被引:32
作者
Gerlach, JC
Botsch, M
Kardassis, D
Lemmens, P
Schön, M
Janke, J
Puhl, G
Unger, J
Kraemer, M
Busse, B
Böhmer, C
Belal, R
Ingenlath, M
Kosan, M
Kosan, B
Sültmann, J
Patzold, A
Tietze, S
Rossaint, R
Müller, C
Mönch, E
Sauer, IM
Neuhaus, P
机构
[1] Humboldt Univ, Surg Clin, Berlin, Germany
[2] Humboldt Univ, Clin Anaesthesiol & Intens Care Med, Berlin, Germany
[3] Humboldt Univ, Inst Clin Biochem, Berlin, Germany
[4] Humboldt Univ, Pediat Clin, Charite, Berlin, Germany
[5] Rhein Westfal TH Aachen, Clin Anaesthesiol & Intens Care Med, D-5100 Aachen, Germany
[6] Clin Surg Havelhohe, Berlin, Germany
关键词
hepatocytes; liver cells; bioreactors; bio-artificial liver; hybrid liver; liver support; animal model;
D O I
10.1177/039139880102401105
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aim of the study was to evaluate a hybrid liver support system in a porcine model of acute liver failure, after hepatectomy. Pigs with a body weight of 70 +/- 18 kg underwent total hepatectomy and porto - cavo - caval shunting as well as ligation of the bile duct and the hepatic artery. Control animals were connected to the system (including capillary membrane plasma separation) containing a four compartment bioreactor with integral oxygenation and decentralized mass exchange but without liver cells. The treatment group received hybrid liver support with the same system including 370 +/- 42 g primary isolated porcine parenchyma! liver cells in co-culture with hepatocyte nursing cells, tissue engineered to liver- like structures at high density. Treatment started after complete recovery from anesthesia and was performed continuously. A positive influence on peripheral vascular resistance and a reduced need of catecholamine dosage was observed in the treatment group. Hybrid liver support with a cell module upscaled for clinical application significantly prolonged survival time in animals after hepatectomy with the longest survival being 26 hours in the control group an 57 hours in the treatment group.
引用
收藏
页码:793 / 798
页数:6
相关论文
共 30 条
[1]   Significantly improved survival time in pigs with complete liver ischemia treated with a novel bioartificial liver [J].
Flendrig, LM ;
Calise, F ;
Di Florio, E ;
Mancini, A ;
Ceriello, A ;
Santaniello, W ;
Mezza, E ;
Sicoli, F ;
Belleza, G ;
Bracco, A ;
Cozzolino, S ;
Scala, D ;
Mazzone, M ;
Fattore, M ;
Gonzales, E ;
Chamuleau, RAFM .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (10) :701-709
[2]   Evaluation of a novel bioartificial liver in rats with complete liver ischemia:: treatment efficacy and species-specific α-GST detection to monitor hepatocyte viability [J].
Flendrig, LM ;
Chamuleau, RAFM ;
Maas, MAW ;
Daalhuisen, J ;
Hasset, B ;
Kilty, CG ;
Doyle, S ;
Ladiges, NCJJ ;
Jörning, GGA ;
la Soe, JW ;
Sommeijer, D ;
te Velde, AA .
JOURNAL OF HEPATOLOGY, 1999, 30 (02) :311-320
[3]   HYBRID LIVER SUPPORT SYSTEM IN A SHORT-TERM APPLICATION ON HEPATECTOMIZED PIGS [J].
GERLACH, J ;
TROST, T ;
RYAN, CJ ;
MEISSLER, M ;
HOLE, O ;
MULLER, C ;
NEUHAUS, P .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1994, 17 (10) :549-553
[4]   High yield hepatocyte isolation from pig livers for investigation of hybrid liver support systems: Influence of collagenase concentration and body weight [J].
Gerlach, J ;
Brombacher, J ;
Smith, M ;
Neuhaus, P .
JOURNAL OF SURGICAL RESEARCH, 1996, 62 (01) :85-89
[5]   SIDE-EFFECTS OF HYBRID LIVER SUPPORT THERAPY - TNF-ALPHA LIBERATION IN PIGS, ASSOCIATED WITH EXTRACORPOREAL BIOREACTORS [J].
GERLACH, J ;
JORRES, A ;
TROST, O ;
HOLE, O ;
VIENKEN, J ;
COURTNEY, JM ;
GAHL, GM ;
NEUHAUS, P .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (08) :604-608
[6]  
GERLACH JC, 1994, INT J ARTIF ORGANS, V17, P301
[7]   Experimental evaluation of a hybrid liver support system [J].
Gerlach, JC ;
Lemmens, P ;
Schon, M ;
Janke, J ;
Rossaint, R ;
Busse, B ;
Puhl, G ;
Neuhaus, P .
TRANSPLANTATION PROCEEDINGS, 1997, 29 (1-2) :852-852
[8]   IMPROVED HEPATOCYTE IN-VITRO MAINTENANCE IN A CULTURE MODEL WITH WOVEN MULTICOMPARTMENT CAPILLARY SYSTEMS - ELECTRON-MICROSCOPY STUDIES [J].
GERLACH, JC ;
SCHNOY, N ;
ENCKE, J ;
SMITH, MD ;
MULLER, C ;
NEUHAUS, P .
HEPATOLOGY, 1995, 22 (02) :546-552
[9]   BIOREACTOR FOR A LARGER SCALE HEPATOCYTE IN-VITRO PERFUSION [J].
GERLACH, JC ;
ENCKE, J ;
HOLE, O ;
MULLER, C ;
RYAN, CJ ;
NEUHAUS, P .
TRANSPLANTATION, 1994, 58 (09) :984-988
[10]  
GERLACH JC, 1994, IN VITRO CELL DEV-AN, V30A, P640