Functional imaging of the retina using the multifocal electroretinograph: A control study

被引:32
作者
Parks, S
Keating, D
Williamson, TH
Evans, AL
Elliott, AT
Jay, JL
机构
[1] W GLASGOW UNIV,NHS TRUST,TENNENT INST OPHTHALMOL,GLASGOW,LANARK,SCOTLAND
[2] UNIV GLASGOW,DEPT CLIN PHYS & BIOENGN,GLASGOW,LANARK,SCOTLAND
关键词
D O I
10.1136/bjo.80.9.831
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background - A new technique exists that enables functional mapping of the retina. A control population was examined to obtain normative values and to assess the reproducibility of this new test. Methods - Twenty healthy volunteers were tested using a 61 hexagonal array stimulus with a 14 minute recording period. Median 5th and 95th percentiles were determined for implicit times and amplitude measures for the 61 test areas. Repeat measurements were performed on 10 individuals. Wilcoxon and Bland and Altman techniques were used to quantify reproducibility of the test. Results - The implicit time of the waveform components was not found to vary over the retina (peak or b-wave component, 35.52 (1.4) ms; trough or a-wave component, 17.76 (0.8) ms). Reproducibility was found to decrease with eccentricity (coefficient of repeatability 17.4% for the central area increasing to 30.3% for the peripheral ring). Conclusions - The findings suggest that reproducibility, although variable with eccentricity, is comparable with conventional electrophysiology. These limits of variation were used to assign confidence intervals to individual retinal areas and will be used (future work) in the examination of diseased states.
引用
收藏
页码:831 / 834
页数:4
相关论文
共 8 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
British Standard Institution, 1979, 5497 BS 1
[3]  
CARR RE, 1990, ELECTRODIAGNOSTIC TE, P38
[4]   HUMAN PHOTORECEPTOR TOPOGRAPHY [J].
CURCIO, CA ;
SLOAN, KR ;
KALINA, RE ;
HENDRICKSON, AE .
JOURNAL OF COMPARATIVE NEUROLOGY, 1990, 292 (04) :497-523
[5]   NEW NONCORNEAL HK-LOOP ELECTRODE FOR CLINICAL ELECTRORETINOGRAPHY [J].
HAWLINA, M ;
KONEC, B .
DOCUMENTA OPHTHALMOLOGICA, 1992, 81 (02) :253-259
[6]   EXPERIENCES WITH THE INTERNATIONAL STANDARD FOR CLINICAL ELECTRORETINOGRAPHY - NORMATIVE VALUES FOR CLINICAL-PRACTICE, INTERINDIVIDUAL AND INTRAINDIVIDUAL VARIATIONS AND POSSIBLE EXTENSIONS [J].
JACOBI, PC ;
MILICZEK, KD ;
ZRENNER, E .
DOCUMENTA OPHTHALMOLOGICA, 1993, 85 (02) :95-114
[7]  
SANDBERG MA, 1979, ARCH OPHTHALMOL-CHIC, V95, P1881
[8]   THE FIELD TOPOGRAPHY OF ERG COMPONENTS IN MAN .1. THE PHOTOPIC LUMINANCE RESPONSE [J].
SUTTER, EE ;
TRAN, D .
VISION RESEARCH, 1992, 32 (03) :433-446