Absolute myoglobin quantitation in serum by combining two-dimensional liquid chromatography-electrospray ionization mass spectrometry and novel data analysis algorithms

被引:66
作者
Mayr, BM
Kohlbacher, O
Reinert, K
Sturm, M
Gröpl, C
Lange, E
Klein, C
Huber, CG
机构
[1] Univ Saarland, Insturmental Anal & Bioanal, D-66041 Saarbrucken, Germany
[2] Univ Saarland, Insturmental Anal & Bioanal, Dept Chem, D-66123 Saarbrucken, Germany
[3] Univ Tubingen, Ctr Bioinformat, Div Simulat Biol Syst, D-75076 Tubingen, Germany
[4] Free Univ Berlin, Inst Comp Sci Algorithms Bioinformat, D-14195 Berlin, Germany
[5] Commiss European Communities, Joint Res Ctr, I-21020 Ispra, Italy
关键词
absolute quantitation; serum; myoglobin; high-performance liquid chromatography; electrospray ionization mass spectrometry; two-dimensional HPLC; standard addition; monoliths; computational proteomics; algorithms;
D O I
10.1021/pr050344u
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To measure myoglobin, a marker for myocardial infarction, directly in human serum, two-dimensional liquid chromatography in combination with electrospray ionization mass spectrometry was applied as an analytical method. High-abundant serum proteins were depleted by strong anion-exchange chromatography. The myoglobin fraction was digested and injected onto a 60 mm x 0.2 mm i.d. monolithic capillary column for quantitation of selected peptides upon mass spectrometric detection. The addition of known amounts of myoglobin to the serum sample was utilized for calibration, and horse myoglobin was added as an internal standard to improve reproducibility. Calibration graphs were linear and facilitated the reproducible and accurate determination of the myoglobin amount present in serum. Manual data evaluation using integrated peak areas and an automated multistage algorithm fitting two-dimensional models of peptide elution profiles and isotope patterns to the mass spectrometric raw data were compared. When the automated method was applied, a myoglobin concentration of 460 pg/mu L serum was determined with a maximum relative deviation from the theoretical value of 10.1% and a maximum relative standard deviation of 13.4%.
引用
收藏
页码:414 / 421
页数:8
相关论文
共 37 条
[1]   Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-MS/MS using protein cleavage and isotope dilution mass spectrometry [J].
Barnidge, DR ;
Goodmanson, MK ;
Klee, GG ;
Muddiman, DC .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (03) :644-652
[2]   Absolute quantification of the G protein-coupled receptor rhodopsin by LC/MS/MS using proteolysis product peptides and synthetic peptide standards [J].
Barnidge, DR ;
Dratz, EA ;
Martin, T ;
Bonilla, LE ;
Moran, LB ;
Lindall, A .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :445-451
[3]  
BARR JR, 1996, J CLIN CHEM, V42, P1676
[4]   Characteristics of myoglobin, carbonic anhydrase III and the myoglobin/carbonic anhydrase III ratio in trauma, exercise, and myocardial infarction patients [J].
Beuerle, JR ;
Azzazy, HME ;
Styba, G ;
Duh, SH ;
Christenson, RH .
CLINICA CHIMICA ACTA, 2000, 294 (1-2) :115-128
[5]   COMBINATION (MULTIPLE) TESTING FOR MYOCARDIAL-INFARCTION USING MYOGLOBIN, CREATINE KINASE-2 (MASS), AND TROPONIN-T [J].
BHAYANA, V ;
COHOE, S ;
PELLAR, TG ;
JABLONSKY, G ;
HENDERSON, AR .
CLINICAL BIOCHEMISTRY, 1994, 27 (05) :395-406
[6]   Identification and relative quantitation of protein mixtures by enzymatic digestion followed by capillary reversed-phase liquid chromatography-tandem mass spectrometry [J].
Bondarenko, PV ;
Chelius, D ;
Shaler, TA .
ANALYTICAL CHEMISTRY, 2002, 74 (18) :4741-4749
[7]   Global protein identification and quantification technology using two-dimensional liquid chromatography nanospray mass spectrometry [J].
Chelius, D ;
Zhang, T ;
Wang, GH ;
Shen, RF .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :6658-6665
[8]   Quantitative profiling of proteins in complex mixtures using liquid chromatography and mass spectrometry [J].
Chelius, D ;
Bondarenko, PV .
JOURNAL OF PROTEOME RESEARCH, 2002, 1 (04) :317-323
[9]   Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS [J].
Gerber, SA ;
Rush, J ;
Stemman, O ;
Kirschner, MW ;
Gygi, SP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (12) :6940-6945
[10]   Differential stable isotope labeling of peptides for quantitation and de novo sequence derivation [J].
Goodlett, DR ;
Keller, A ;
Watts, JD ;
Newitt, R ;
Yi, EC ;
Purvine, S ;
Eng, JK ;
von Haller, P ;
Aebersold, R ;
Kolker, E .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) :1214-1221