Design of a contactless battery charger for cellular phone

被引:256
作者
Kim, CG [1 ]
Seo, DH [1 ]
You, JS [1 ]
Park, JH [1 ]
Cho, BH [1 ]
机构
[1] Seoul Natl Univ, Sch Elect Engn, Seoul 151742, South Korea
关键词
battery-charging control; contactless charger; loosely coupled transformer; series resonant; transformer design;
D O I
10.1109/41.969404
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, the design of a contactless charger for the lithium-ion battery of a cellular phone is presented. In this charger, the primary core of the transformer is in the charger unit and the secondary core is in the telephone. The gap (3 mm) between them is the thickness of the two plastic cases. The transformer core design for the maximum coupling coefficient with the size constraint on the secondary side is presented. Analysis of the primary-side series resonant converter with the loosely coupled transformer is performed, and the design optimization is presented. For the battery-charging control, a simple control circuit is presented and its performance is verified from the experimental results.
引用
收藏
页码:1238 / 1247
页数:10
相关论文
共 18 条
[1]  
Abe H., 1998, P IEEE APEC 98, V1, P136
[2]  
CARTER B, 1996, P IECEC 96, V1, P362
[3]   Design of transcutaneous energy transmission system using a series resonant converter [J].
Ghahary, Ali ;
Cho, Bo H. .
IEEE Transactions on Power Electronics, 1992, 7 (02) :261-269
[4]   Practical study on wireless transmission of power and information for autonomous decentralized manufacturing system [J].
Hirai, J ;
Kim, TW ;
Kawamura, A .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1999, 46 (02) :349-359
[5]   NUMERICAL-METHOD FOR THE PERFORMANCE OF A SEPARATE-TYPE TRANSFORMER CONNECTED TO BATTERY CHARGER [J].
HIRATA, K ;
MITSUTAKE, Y ;
ISHIHARA, Y ;
TODAKA, T .
IEEE TRANSACTIONS ON MAGNETICS, 1995, 31 (03) :2123-2126
[6]   An energy transmission system for an artificial heart using leakage inductance compensation of transcutaneous transformer [J].
Joung, GB ;
Cho, BH .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (06) :1013-1022
[7]  
Kim CG, 1996, PROC IECEC, P587, DOI 10.1109/IECEC.1996.552959
[8]  
KIM CG, 2000, COMP STUDY RESONANT
[9]   Signal transmission for implantable medical devices using figure-of-eight coils [J].
Matsuki, H ;
Ofuji, K ;
Chubachi, N ;
Nitta, S .
IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (05) :5121-5123
[10]   DEVELOPMENT OF AN IMPLANTABLE MOTOR-DRIVEN ASSIST PUMP SYSTEM [J].
MITAMURA, Y ;
OKAMOTO, E ;
HIRANO, A ;
MIKAMI, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (02) :146-156