Rapid vessel prototyping:: vascular modeling using 3t magnetic resonance angiography and rapid prototyping technology

被引:39
作者
Markl, M
Schumacher, R
Küffer, J
Bley, TA
Hennig, J
机构
[1] Univ Hosp Freiburg, Dept Diagnost Radiol Med Phys, D-79106 Freiburg, Germany
[2] Fachhsch Beider Basel FHBB, Dept Ind, Abt Maschinenbau Rapid Prod Dev, Muttenz, Switzerland
关键词
MRI; MRA; angiography; 3D computer; model; rapid prototyping; thoracic aorta;
D O I
10.1007/s10334-005-0019-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Object: Conversion of thoracic aortic vasculature as measured by Magnetic Resonance Imaging into a real physical replica. Materials and methods: Several procedural steps including data acquisition with contrast enhanced MR Angiography at 3T, data visualization and 3D computer model generation, as well as rapid prototyping were used to construct an in-vitro model of the vessel geometry Results: A rapid vessel prototyping process was implemented and used to convert complex vascular geometry of the entire thoracic aorta and major branching arteries into a real physical replica with large anatomical coverage and high spatial resolution. Conclusion: Rapid vessel prototyping permits the creation of a concrete solid replica of a patient's vascular anatomy.
引用
收藏
页码:288 / 292
页数:5
相关论文
共 19 条
[1]  
Barker T. M., 1993, Australasian Physical and Engineering Sciences in Medicine, V16, P79
[2]   Computer aided design and fabrication of models for in vitro studies of vascular fluid dynamics [J].
Chong, CK ;
Rowe, CS ;
Sivanesan, S ;
Rattray, A ;
Black, RA ;
Shortland, AP ;
How, TV .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H1) :1-4
[3]   Cerebrovascular biomodelling: A technical note [J].
D'Urso, PS ;
Thompson, RG ;
Atkinson, RL ;
Weidmann, MJ ;
Redmond, MJ ;
Hall, BI ;
Jeavons, SJ ;
Benson, MD ;
Earwaker, WJS .
SURGICAL NEUROLOGY, 1999, 52 (05) :490-500
[4]  
Elkins CJ, 2003, EXP FLUIDS, V34, P494, DOI [10.1007/S00348-003-0587-z, 10.1007/S00348-003-0587-Z]
[5]  
Frangi AF, 2001, MAGNET RESON MED, V45, P311, DOI 10.1002/1522-2594(200102)45:2<311::AID-MRM1040>3.0.CO
[6]  
2-7
[7]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[8]   Accuracy of plastic replica of aortic aneurysm using 3D-CT data for transluminal stent-grafting: Experimental and clinical evaluation [J].
Kato, K ;
Ishiguchi, T ;
Maruyama, K ;
Naganawa, S ;
Ishigaki, T .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (02) :300-304
[9]  
Knox K, 2005, AM J NEURORADIOL, V26, P1428
[10]   Time-resolved three-dimensional phase-contrast MRI [J].
Markl, M ;
Chan, FP ;
Alley, MT ;
Wedding, KL ;
Draney, MT ;
Elkins, CJ ;
Parker, DW ;
Wicker, R ;
Taylor, CA ;
Herfkens, RJ ;
Pelc, NJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) :499-506