Theoretical background and conceptual solution for depth perception and eye-hand coordination problems in laparoscopic surgery

被引:52
作者
Breedveld, P [1 ]
Stassen, HG [1 ]
Meijer, DW [1 ]
Stassen, LPS [1 ]
机构
[1] Delft Univ Technol, Fac Design Engn & Prod, Man Machine Syst & Control Grp, NL-2628 CD Delft, Netherlands
关键词
laparoscopic surgery; depth perception; eye-hand coordination; misorientations; movement parallax; endoscope positioning system;
D O I
10.3109/13645709909153166
中图分类号
R61 [外科手术学];
学科分类号
摘要
The indirect method of observation and manipulation in laparoscopic surgery complicates the surgeon's depth perception and impairs his/her eye-hand coordination. Depth perception problems are due to misfits in accommodation and convergence, absence of shadows in endoscopic camera pictures and absence of stereo-vision and movement parallax. Eye-hand coordination problems are caused by the distant location of the monitor and by the fact that the surgeon's hand movements are rotated, mirrored and amplified when they appear on the monitor These effects are very confusing, especially for trainee laparoscopic surgeons and require a long and intensive training period to overcome. This paper gives a theoretical background of the depth perception and eye-hand coordination problems. A technical concept of an endoscope positioning system is described that compensates misorientations by using a flexible 90 degrees endoscope. Movement parallax is achieved using a motorised endoscope positioner controlled by the surgeon's head movements.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 23 条
[1]  
BAJURA M, 1996, COMPUTER INTEGRATED, P245
[2]  
Breedveld P., 1997, P EUR C HUM DEC MAK, P219
[3]  
BREEDVELD P, 1998, N510 DELFT U TECHN F
[4]   COMPARISON OF DIRECT VISION AND ELECTRONIC 2-DIMENSIONAL AND 3-DIMENSIONAL DISPLAY SYSTEMS ON SURGICAL TASK EFFICIENCY IN ENDOSCOPIC SURGERY [J].
CROSTHWAITE, G ;
CHUNG, T ;
DUNKLEY, P ;
SHIMI, S ;
CUSCHIERI, A .
BRITISH JOURNAL OF SURGERY, 1995, 82 (06) :849-851
[5]   Visual display technology for endoscopic surgery [J].
Cuschieri, A .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1996, 5 (05) :427-434
[6]  
CUSCHIERI A, 1992, OPERATIVE MANUAL END
[7]   CONTROLLING THE MOVEMENT OF A SURGICAL LAPAROSCOPE - ENDOSISTA(TM) WITH 4 DEGREES OF FREEDOM, OPERATES IN CONCERT WITH SURGEONS INTUITIVE HEAD MOTIONS [J].
FINLAY, PA ;
ORNSTEIN, MH .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (03) :289-291
[8]   Technological aspects of minimal access surgery [J].
Frank, TG ;
Hanna, GB ;
Cuschieri, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (02) :129-144
[9]  
Gibson J. J., 1977, ECOLOGICAL APPROACH
[10]   Task performance in endoscopic surgery is influenced by location of the image display [J].
Hanna, GB ;
Shimi, SM ;
Cuschieri, A .
ANNALS OF SURGERY, 1998, 227 (04) :481-484