摘要
The dielectric parameters of the tissue simulating liquids to assess the exposure from mobile phones were determined in a previous study considering the tissue distribution of the exposed regions of the head using a planar layered model and the transmission-line method. Currently, the standards for the compliance testing of wireless devices are being extended to more general exposure situations. This paper uses the same methods considering different locations of the body and the respective variations of the tissue structures and dimensions. The analysis of tissue compositions shows a significant increase of 2.2-4.7 dB of the peak spatial specific absorption rate (SAR) in comparison to the values assessed with current standard liquids. This increase is due to standing-wave effects in tissues with low water content. For a certain distance between the antenna and the body (approximately lambda/3 for a lambda/2 dipole), these standing-wave effects dominate the coupling mechanism, leading to a higher average SAR in layered tissue. The observations were validated using finite-difference time-domain simulations of an anatomical high-resolution human model. Nevertheless, a sound conservative exposure assessment applying phantoms filled with homogeneous standardized liquids is possible if a distance and frequency-dependent scaling factor is applied.
引用
收藏
页码:2188 / 2195
页数:8
相关论文
共 33 条
[1]   Time course for strength and muscle thickness changes following upper and lower body resistance training in men and women [J].
Abe, T ;
DeHoyos, DV ;
Pollock, ML ;
Garzarella, L .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 2000, 81 (03) :174-180
[2]   The visible human project [J].
Ackerman, MJ .
PROCEEDINGS OF THE IEEE, 1998, 86 (03) :504-511
[3]  
[Anonymous], 2002, C9532002IEEE
[4]  
[Anonymous], 2002, STDT56 ARIB
[5]  
[Anonymous], 1993, Fields and Waves in Communication Electronics
[6]   ELECTROMAGNETIC ABSORPTION IN A MULTILAYERED MODEL OF MAN [J].
BARBER, PW ;
GANDHI, OP ;
HAGMANN, MJ ;
CHATTERJEE, I .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (07) :400-405
[7]  
BEARD B, UNPUB IEEE T ELECTRO
[8]   M-mode ultrasound: a reliable measure of transversus abdominis thickness? [J].
Bunce, SM ;
Moore, AP ;
Hough, AD .
CLINICAL BIOMECHANICS, 2002, 17 (04) :315-317
[9]  
Chatterjee I, 1980, Bioelectromagnetics, V1, P363, DOI 10.1002/bem.2250010403
[10]  
Chatterjee I, 1980, Bioelectromagnetics, V1, P379, DOI 10.1002/bem.2250010404