Determination of the ionic resistance in a porous electrode using chronocoulometry

被引:22
作者
Jin, XB [1 ]
Zhuang, L [1 ]
Lu, JT [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
porous electrodes; ionic resistance; chronocoulometry;
D O I
10.1016/S0022-0728(01)00726-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The purpose of the work is to establish a simplified method, which is easy to use and yet sufficiently accurate for the determination of ionic resistance in porous electrodes. The equation of the chronocoulometric transient following a potential step is deduced for porous electrodes in the double layer region based on a one-dimensional transmission line model. According to the result of numerical calculations, the internal ionic resistance is R-p = 2.550t(0.69)/C-total - 2.986R(e) where t(0.69) is the time of 69% response on the charge-time curve. The total double layer capacitance (C-total) can be obtained from the equation C-total = Q/eta(0), where Q is the plateau charge on the chronocoulometric curve and eta(0) is the amplitude of the potential step. R-e is the uncompensated solution resistance between the Luggin tip and the front surface of the porous electrode, and R-e = eta(0)/I(0) where I(0) is the current at the beginning of the potential step. The theoretical error of the approximate equation is below 0.7%. The validity of the proposed method is well supported by the experimental data obtained for a porous silver electrode in I and 6 mol l(-1) KOH solutions. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 18 条