Numerical evaluation of ECT impedance signal due to minute cracks

被引:26
作者
Fukutomi, H
Takagi, T
Tani, J
Hashimoto, M
Shimone, J
Harada, Y
机构
[1] TOHOKU UNIV,INST FLUID SCI,AOBA KU,SENDAI,MIYAGI 98077,JAPAN
[2] POLYTECH UNIV,SAGAMIHARA,KANAGAWA 229,JAPAN
[3] NUCL ENGN LTD,OSAKA 550,JAPAN
关键词
D O I
10.1109/20.582750
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes an experimental and analytical study on minute crack inspection with Eddy Current Testing (ECT). Measurement and simulation using a 3D FEM program are applied for the evaluation of the detecting signal with a minute crack in a test piece. Parameters such as mesh division, ICCG convergence criteria, etc. are evaluated to achieve high accuracy in numerical calculation. The simulation results agreed with experimental ones.
引用
收藏
页码:2123 / 2126
页数:4
相关论文
共 6 条
[1]   ON THE USE OF THE MAGNETIC VECTOR POTENTIAL IN THE FINITE-ELEMENT ANALYSIS OF 3-DIMENSIONAL EDDY CURRENTS [J].
BIRO, O ;
PREIS, K .
IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (04) :3145-3159
[2]  
Burke S. K., 1988, J NONDESTRUCT EVAL, V7, P35, DOI 10.1007/BF00565775
[3]  
HARADA Y, 1995, J JAPAN SOC APPL ELE, V3, P91
[4]  
HASHIMOTO M, 1994, REV PROG Q, V13, P287
[5]  
Takagi T., 1994, International Journal of Applied Electromagnetics in Materials, V5, P149
[6]   A COIL OVER A CRACK - (RESULTS FOR BENCHMARK PROBLEM-8 OF TEAM WORKSHOP) [J].
VERITE, JC .