Non-invasive assessment of liver fibrosis by stiffness measurement in patients with chronic hepatitis B

被引:400
作者
Marcellin, Patrick [2 ,3 ]
Ziol, Marianne [4 ,5 ]
Bedossa, Pierre [6 ]
Douvin, Catherine [7 ]
Poupon, Raoul [8 ]
de Ledinghen, Victor [1 ]
Beaugrand, Michel [9 ,10 ]
机构
[1] Haut Leveque Hop, Ctr Invest Fibrose Hepat, Dept Gastroenterol & Hepatol, F-33604 Pessac, France
[2] Univ Paris, Hop Beaujon, AP HP, Serv Hepatol, Clichy, France
[3] Univ Paris, Hop Beaujon, AP HP, INSERM,U773, Clichy, France
[4] Univ Paris 13, UPRES EA 3406, Bondy, France
[5] Jean Verdier Hosp, AP HP, Dept Pathol, Bondy, France
[6] Hop Beaujon, AP HP, Dept Pathol, Clichy, France
[7] Hop Henri Mondor, AP HP, Dept Gastroenterol & Hepatol, F-94010 Creteil, France
[8] Hop St Antoine, AP HP, Dept Gastroenterol & Hepatol, F-75571 Paris, France
[9] Univ Paris 13, UPRES EA 3410, Bondy, France
[10] Jean Verdier Hosp, AP HP, Dept Gastroenterol & Hepatol, Bondy, France
关键词
chronic hepatitis B; fibrosis; liver biopsy; liver stiffness; transient elastography; CHRONIC VIRAL-HEPATITIS; TRANSIENT ELASTOGRAPHY; SAMPLING VARIABILITY; BIOPSY; CIRRHOSIS; DIAGNOSIS; DISEASE; INFECTION; MARKER; INDEX;
D O I
10.1111/j.1478-3231.2008.01802.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The need for new non-invasive tools to assess liver fibrosis in chronic liver diseases has been largely advocated. Liver stiffness measurement (LSM) using transient elastography (FibroScan((R)), Echosens((TM))) has been shown to be correlated to liver fibrosis in various chronic liver diseases. This study aims to assess its diagnosis accuracy in patients with chronic hepatitis B. We prospectively enrolled 202 patients with chronic hepatitis B in a multicentre study. Patients underwent liver biopsy (LB) and LSM. METAVIR and Ishak liver fibrosis stages were assessed by two pathologists. LSM or LB was considered unreliable in 29 patients. Statistical analysis was conducted in 173 patients. LSM was significantly (P < 0.001) correlated with METAVIR (r=0.65) and Ishak fibrosis stage (0.65). The area under receiver-operating characteristic curves were 0.81 (95% confidence intervals, 0.73-0.86) for F >= 2, 0.93 (0.88-0.96) for F >= 3 and 0.93 (0.82-0.98) for F=4. Optimal LSM cut-off values were 7.2 and 11.0 kPa for F >= 2 and F=4, respectively, by maximizing the sum D of sensitivity and specificity, and 7.2 and 18.2 kPa by maximizing the diagnosis accuracy. In conclusion, LSM appears to be reliable for detection of significant fibrosis or cirrhosis in HBV patients and cut-off values are only slightly different from those observed in HCV patients.
引用
收藏
页码:242 / 247
页数:6
相关论文
共 33 条
[21]   Comparison of test performance profile for blood tests of liver fibrosis in chronic hepatitis C [J].
Halfon, Philippe ;
Bacq, Yannick ;
De Muret, Anne ;
Penaranda, Guillaume ;
Bourliere, Marc ;
Ouzan, Denis ;
Tran, Albert ;
Botta, Danielle ;
Renou, Christophe ;
Brechot, Marie-Claude ;
Degott, Claude ;
Paradis, Valerie .
JOURNAL OF HEPATOLOGY, 2007, 46 (03) :395-402
[22]   HISTOLOGICAL GRADING AND STAGING OF CHRONIC HEPATITIS [J].
ISHAK, K ;
BAPTISTA, A ;
BIANCHI, L ;
CALLEA, F ;
DEGROOTE, J ;
GUDAT, F ;
DENK, H ;
DESMET, V ;
KORB, G ;
MACSWEEN, RNM ;
PHILLIPS, MJ ;
PORTMANN, BG ;
POULSEN, H ;
SCHEUER, PJ ;
SCHMID, M ;
THALER, H .
JOURNAL OF HEPATOLOGY, 1995, 22 (06) :696-699
[23]  
KONATE A, 2006, 57 ANN M AM ASS STUD
[24]  
MAHARAJ B, 1986, LANCET, V1, P523
[25]   Ultrasound evaluation of the fibrosis stage in chronic liver disease by the simultaneous use of low and high frequency probes [J].
Nishiura, T ;
Watanabe, H ;
Ito, M ;
Matsuoka, Y ;
Yano, K ;
Daikoku, M ;
Yatsuhashi, H ;
Dohmen, K ;
Ishibashi, H .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (927) :189-197
[26]  
Regev A, 2002, AM J GASTROENTEROL, V97, P2614, DOI 10.1111/j.1572-0241.2002.06038.x
[27]   Noninvasive measures of liver fibrosis [J].
Rockey, DC ;
Bissell, DM .
HEPATOLOGY, 2006, 43 (02) :S113-S120
[28]   Sources of variability in histological scoring of chronic viral hepatitis [J].
Rousselet, MC ;
Michalak, S ;
Dupré, F ;
Croué, A ;
Bedossa, P ;
Saint-André, JP ;
Calès, P .
HEPATOLOGY, 2005, 41 (02) :257-264
[29]   Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage [J].
Sagir, Abdurrahman ;
Erhardt, Andreas ;
Schmitt, Marcus ;
Haeussinger, Dieter .
HEPATOLOGY, 2008, 47 (02) :592-595
[30]   Transient elastography: A new noninvasive method for assessment of hepatic fibrosis [J].
Sandrin, L ;
Fourquet, B ;
Hasquenoph, JM ;
Yon, S ;
Fournier, C ;
Mal, F ;
Christidis, C ;
Ziol, M ;
Poulet, B ;
Kazemi, F ;
Beaugrand, M ;
Palau, R .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (12) :1705-1713