Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: Effects of magnetic field variation

被引:106
作者
An, HY
Lin, WL
机构
[1] Univ N Carolina, Dept Radiol & Biomed Engn, Chapel Hill, NC 27599 USA
[2] Washington Univ, Dept Biomed Engn, St Louis, MO USA
关键词
BOLD; background field inhomogeneity; cerebral venous blood volume;
D O I
10.1002/mrm.10148
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The presence of magnetic background field inhomogeneity (DeltaB) may confound quantitative measures of cerebral venous blood volume (vCBV) and cerebral oxygen extraction fraction (MR_OEF) with T-2*-based methods. The goal of this study was to correct its effect and obtain more accurate estimates of vCBV and MR_OEF. A 3D high-resolution gradient echo sequence was employed to obtain DeltaB maps by two algorithms. The DeltaB maps were then used to recover the signal loss in images acquired by a 2D multiecho gradient echo / spin echo sequence. Finally, both quantitative estimates of MR_OEF and vCBV were obtained from the DeltaB-corrected 2D multiecho gradient echo / spin echo images. A total of 12 normal subjects were studied. An overestimated vCBV was observed in the brain (4.29 +/- 0.78%) prior to DeltaB correction, while the measured vCBV was substantially reduced after DeltaB correction. Whole brain vCBV of 2.97 +/- 0.44% and 2.68 +/- 0.47% were obtained by the two different DeltaB correction methods, in excellent agreement with the reported results in the literature. Furthermore, when MR_OEF was compared with and without DeltaB correction, no significant differences (P = 0.467) were observed. The ability to simultaneously obtain vCBV and MR_OEF noninvasively may have profound clinical implications for the studies of cerebrovascular disease. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:958 / 966
页数:9
相关论文
共 41 条
[1]   Quantitative measurements of cerebral blood oxygen saturation using magnetic resonance imaging [J].
An, HY ;
Lin, WL .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2000, 20 (08) :1225-1236
[2]   MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[3]  
BRCOKS DJ, 1985, NEUROLOGY, V35, P1030
[4]   REDUCTION OF SUSCEPTIBILITY ARTIFACT IN GRADIENT-ECHO IMAGING [J].
CHO, ZH ;
RO, YM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :193-200
[5]  
Constable RT, 1999, MAGNET RESON MED, V42, P110, DOI 10.1002/(SICI)1522-2594(199907)42:1<110::AID-MRM15>3.0.CO
[6]  
2-3
[7]  
Duong TQ, 2000, MAGNET RESON MED, V43, P393, DOI 10.1002/(SICI)1522-2594(200003)43:3<393::AID-MRM11>3.0.CO
[8]  
2-K
[9]   INVIVO DETERMINATION OF CEREBRAL BLOOD-VOLUME WITH RADIOACTIVE OXYGEN-15 IN MONKEY [J].
EICHLING, JO ;
RAICHLE, ME ;
GRUBB, RL ;
LARSON, KB ;
TERPOGOSSIAN, MM .
CIRCULATION RESEARCH, 1975, 37 (06) :707-714
[10]  
Fernández-Seara MA, 2000, MAGNET RESON MED, V44, P358, DOI 10.1002/1522-2594(200009)44:3<358::AID-MRM3>3.0.CO