Reliability of three lumbar sagittal motion measurement methods: Surface inclinometers

被引:25
作者
Chen, SPC
Samo, DG
Chen, EH
Crampton, AR
Conrad, KM
Egan, L
Mitton, J
机构
[1] OMEGA,GLENVIEW,IL 60025
[2] UNIV ILLINOIS,COLL MED,CHICAGO,IL 60612
[3] UNIV ILLINOIS,SCH PUBL HLTH,CHICAGO,IL
[4] NORTHWESTERN UNIV,EVANSTON HOSP,EVANSTON,IL 60201
[5] NORTHWESTERN UNIV,DEPT MED,EVANSTON,IL
[6] NORTHWESTERN UNIV,DEPT RADIOL,EVANSTON,IL
关键词
D O I
10.1097/00043764-199703000-00011
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Three surface methods for measuring lumbar sagittal motion (LSM) were tested for reliability, The three methods used were the Pleurimeter V double inclinometer, the carpenter double inclinometer, and the computerized single sensor inclinometer, In this study, 30 volunteers were examined independently by three occupational health professionals. Each volunteer rotated twice through three stations at which LSM was measured by each of the three methods. The intra- and interexaminer reliabilities in identifying the skin levels of T12 and S1 were acceptable, having intraclass correlation coefficients (ICC) greater than or equal to 0.75, With a single exception, all ICC values for the intraexaminer reliability of LSM measurements fell below 0.90 (a clinically desirable level). The interexaminer reliability was poor, with all ICC values below 0.75, The largest source of measurement error was attributable to the examiner and its associated factors. We concluded that the intra- and interexaminer reliabilities varied greatly, limiting the clinical usefulness of the three surface methods.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 22 条
[1]  
American Medical Association, 1993, GUID EV PERM IMP
[2]  
*BISS HEALTHC CORP, 1991, 86011191 BISS HEALTH
[3]  
*CAMBR SCI IND, 1985, LARG SKINF CAL OP MA
[4]  
CARMINEE EG, 1979, RELIABILITY VALIDITY
[5]  
CRONBACH LJ, 1972, DEPENDABILITY BEHAVI
[6]   MOTION OF THE LUMBAR SPINE - RELIABILITY OF 2 MEASUREMENT TECHNIQUES [J].
DILLARD, J ;
TRAFIMOW, J ;
ANDERSSON, GBJ ;
CRONIN, K .
SPINE, 1991, 16 (03) :321-324
[7]   REPEATABILITY OF 4 CLINICAL METHODS FOR ASSESSMENT OF LUMBAR SPINAL MOTION [J].
GILL, K ;
KRAG, MH ;
JOHNSON, GB ;
HAUGH, LD ;
POPE, MH .
SPINE, 1988, 13 (01) :50-53
[8]  
HANLEY EN, 1976, CLIN ORTHOP RELAT R, V115, P145
[9]   VARIANCE IN THE MEASUREMENT OF SAGITTAL LUMBAR SPINE RANGE OF MOTION AMONG EXAMINERS, SUBJECTS, AND INSTRUMENTS [J].
MAYER, RS ;
CHEN, IH ;
LAVENDER, SA ;
TRAFIMOW, JH ;
ANDERSSON, GBJ .
SPINE, 1995, 20 (13) :1489-1493
[10]   USE OF NONINVASIVE TECHNIQUES FOR QUANTIFICATION OF SPINAL RANGE-OF-MOTION IN NORMAL SUBJECTS AND CHRONIC LOW-BACK DYSFUNCTION PATIENTS [J].
MAYER, TG ;
TENCER, AF ;
KRISTOFERSON, S ;
MOONEY, V .
SPINE, 1984, 9 (06) :588-595