Differential pulse voltammetric determination of trace Te(IV) at a poly (3,3′-diaminobenzidine) film modified gold electrode in flow systems

被引:20
作者
Khoo, SB [1 ]
Ye, RD [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
关键词
trace tellurium determination; flow methods; poly(3,3 '-diaminobenzidine) film; differential pulse anodic voltammetry; gold electrode; medium exchange;
D O I
10.1016/S0003-2670(01)01396-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electropolymerization of 3,3'-diaminobenzidine on a gold surface gave an adherent, stable film of poly(3,3'-diaminobenzidine) (PDAB). This polymer film retained the complexational functionalities of its monomer, demonstrating preconcentration abilities for several ions, including Se(IV) and Te(IV). In particular, in this work, continuous flow and flow injection methods were developed for the sensitive and selective determination of Te(IV). The optimized method for the continuous flow mode had a detection limit of 5.6 x 10(-9) mol 1(-1) for 10 min preconcentration. Typical relative standard deviations for six consecutive determinations were 1.82 and 2.56% for Te(IV) concentrations of 1.0 x 10(-6) and 5.0 x 10(-8) mol 1(-1), respectively (10 min preconcentration). The method was applied to the determination of Te(IV) in real samples. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:209 / 220
页数:12
相关论文
共 25 条
[1]   COORDINATION CHEMISTRY IN 2 DIMENSIONS - CHEMICALLY MODIFIED ELECTRODES [J].
ABRUNA, HD .
COORDINATION CHEMISTRY REVIEWS, 1988, 86 :135-189
[2]   VOLTAMMETRIC DETERMINATION OF TRACE-METALS AND ORGANICS AFTER ACCUMULATION AT MODIFIED ELECTRODES [J].
ARRIGAN, DWM .
ANALYST, 1994, 119 (09) :1953-1966
[3]  
CAI Q, UNPUB
[4]   POLY(3,3'-DIAMINOBENZIDINE) FILM ON A GOLD ELECTRODE FOR SELECTIVE PRECONCENTRATION AND STRIPPING ANALYSIS OF SELENIUM(IV) [J].
CAI, QT ;
KHOO, SB .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4543-4550
[5]  
D'Ulivo A, 1997, ANALYST, V122, p117R, DOI 10.1039/a704759b
[6]   DIFFERENTIAL PULSE POLAROGRAPHIC-DETERMINATION OF ARSENIC, SELENIUM AND TELLURIUM AT MU-G LEVELS [J].
FERRI, T ;
MORABITO, R ;
PETRONIO, BM ;
PITTI, E .
TALANTA, 1989, 36 (12) :1259-1263
[7]  
FISHBEIN L, 1991, METALS THEIR COMPOUN, P1211
[8]   SENSING WITH CHEMICALLY AND BIOLOGICALLY MODIFIED CARBON ELECTRODES [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1995, 120 (04) :1029-1045
[9]   COMPARATIVE-STUDY OF 1ST-GENERATION, 2ND-GENERATION AND 3RD-GENERATION AMPEROMETRIC GLUCOSE ENZYME ELECTRODES IN CONTINUOUS-FLOW ANALYSIS OF UNDILUTED WHOLE-BLOOD [J].
GUNASINGHAM, H ;
TAN, CH ;
AW, TC .
ANALYTICA CHIMICA ACTA, 1990, 234 (02) :321-330
[10]   DETERMINATION OF SELENIUM AND TELLURIUM IN ELECTROLYTIC COPPER BY ANODIC-STRIPPING VOLTAMMETRY AT A GOLD FILM ELECTRODE [J].
HAMILTON, TW ;
ELLIS, J ;
FLORENCE, TM .
ANALYTICA CHIMICA ACTA, 1979, 110 (01) :87-94