Assessment of bone quality in the proximal humerus by measurement of the contralateral site: a cadaveric analyze

被引:43
作者
Diederichs, G
Korner, J
Goldhahn, J
Linke, B
机构
[1] Inst Radiol, D-10098 Berlin, Germany
[2] AO Res Inst, Davos, Switzerland
[3] Johannes Gutenberg Univ Mainz, Clin Trauma & Reconstruct Surg, D-6500 Mainz, Germany
[4] Schulthess Clin, Zurich, Switzerland
关键词
BMD; bone quality; humerus fracture; osteosynthesis; osteoporosis;
D O I
10.1007/s00402-006-0103-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: The presence of osteoporosis decreases the success of osteosynthesis, especially in the proximal humerus. Estimation of the bone mineral density (BMD) at the fracture site could aid in the decision making for surgical treatment and potential implant choice with regard to the individual bone properties. BMD measurement at a fracture site is prone to inaccuracies and alternative measurement sites need to be identified. In the case of a proximal humerus fracture, promising alternative measurement sites are at the same contralateral or at a different ipsilateral location. The aim of this study was to determine if the BMD for the humeral head can be predicted by BMD measurements from the ipsilateral distal humerus or the contralateral proximal humerus. Material and methods: Cancellous BMD values were obtained from 88 paired human cadaver humeri ( age 75.8 +/- 13.5 years) at the humeral head and at the distal metaphyseal area by pQCT. Correlations between BMD values of the ipsi- and contralateral sites were computed. Results: Correlations between proximal and distal BMD values within one bone were moderate for both left (R-2 = 0.37) and right humeri (R-2 = 0.40). BMD comparison between left and right humeri revealed high correlations for both the distal (R-2 = 0.90) and the proximal humerus (R-2 = 0.74) ( all P< 0.01). Elderly specimen (>= 70 years) showed better intersite correlations between all regions than younger specimen (< 70 years). Conclusion: High correlations between contralateral BMD values may be the result of similar biomechanical loading conditions. Although a relationship between proximal and distal bone quality of the same bone was found, the moderate coefficient suggests that ipsilateral measurements do not provide a good prediction of humeral head BMD. Bone quality at the humeral head is best predicted by BMD measurements at the contralateral location rather than the ipsilateral distal site.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 33 条
[1]
Site of osteodensitometry in perimenopausal women: Correlation and limits of agreement between anatomic regions [J].
Abrahamsen, B ;
Hansen, TB ;
Jensen, LB ;
Hermann, AP ;
Eiken, P .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (09) :1471-1479
[2]
Heterogeneity of the skeleton: Comparison of the trabecular microarchitecture of the spine, the iliac crest, the femur, and the calcaneus [J].
Amling, M ;
Herden, S ;
Posl, M ;
Hahn, M ;
Ritzel, H ;
Delling, G .
JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 (01) :36-45
[3]
Broadbent M R, 2003, Scand J Surg, V92, P220
[4]
Prediction of vertebral and femoral strength in vitro by bone mineral density measured at different skeletal sites [J].
Cheng, XG ;
Lowet, G ;
Boonen, S ;
Nicholson, PHF ;
van der Perre, G ;
Dequeker, J .
JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (09) :1439-1443
[5]
EVALUATION OF ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF HUMAN TRABECULAR BONE FROM THE MAJOR METAPHYSEAL REGIONS WITH MATERIALS TESTING AND COMPUTED-TOMOGRAPHY [J].
CIARELLI, MJ ;
GOLDSTEIN, SA ;
KUHN, JL ;
CODY, DD ;
BROWN, MB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :674-682
[6]
Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry [J].
Eckstein, F ;
Lochmüller, EM ;
Lill, CA ;
Kuhn, V ;
Schneider, E ;
Delling, G ;
Müller, R .
JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 (01) :162-171
[7]
Cadaveric-biomechanical evaluation of bone-implant construct of proximal humerus fractures (Neer type 3) [J].
Fankhauser, F ;
Schippinger, G ;
Weber, K ;
Heinz, S ;
Quehenberger, F ;
Boldin, C ;
Bratschitsch, G ;
Szyszkowitz, R ;
Georg, L ;
Friedrich, A .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 55 (02) :345-349
[8]
A comparison of open reduction and internal fixation and primary total elbow arthroplasty in the treatment of intraarticular distal humerus fractures in women older than age 65 [J].
Frankle, MA ;
Herscovici, D ;
DiPasquale, TG ;
Vasey, MB ;
Sanders, RW .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (07) :473-480
[9]
Friedman WJ, 2003, PROGRESS INFANCY RES, V3, P55
[10]
Assessment of calibration methods for estimating bone mineral densities in trauma patients with quantitative CT: An anthropomorphic phantom study [J].
Goodsitt, MM ;
Christodoulou, EG ;
Larson, SC ;
Kazerooni, EA .
ACADEMIC RADIOLOGY, 2001, 8 (09) :822-834