Studies on buoyancy driven two-directional smoke flow layering length with combination of point extraction and longitudinal ventilation in tunnel fires

被引:102
作者
Chen, L. F. [1 ]
Hu, L. H. [1 ]
Tang, W. [1 ]
Yi, L. [2 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[2] Cent South Univ, Inst Disaster Prevent Sci & Safety Technol, Changsha 230026, Hunan, Peoples R China
关键词
Tunnel fire; Point extraction; Longitudinal ventilation; Smoke flow layering length; Model tunnel experiments; FDS; TEMPERATURE; TESTS; FIELD;
D O I
10.1016/j.firesaf.2013.04.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the buoyancy-driven smoke flow layering length (both upstream and downstream) beneath the ceiling with combination of point extraction and longitudinal ventilation in tunnel fires. A theoretical model is developed based on previous back-laying model with only longitudinal ventilation, with modified actual heat release rate, as well as modified upstream and downstream opposing longitudinal air flow velocities by the induced flow velocity due to point extraction. Experiments are carried out in a reduced scale model tunnel with dimensionless of 72 m x 1.5 m x 1.3 m. A LPG porous gas burner is used as fire source. The smoke flow layering length both upstream and downstream are identified based on temperature profiles measured along the ceiling, for different experiment conditions. CFD simulations with FDS are also performed for the same scenarios. Results show that with combination of point extraction and longitudinal ventilation, the smoke flow layering length is not symmetric where it is longer downstream than that upstream. The upstream smoke layering length decreases, while the downstream layering length increases with increase in longitudinal ventilation velocity; and they both decrease with increase in point extraction velocity. The predictions by the proposed theoretical model agree well with the measurements and simulation results. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 29 条
[1]  
[Anonymous], FIRE SAF J
[2]  
Carvel R, 2005, A History of Fire Incidents in Tunnels
[3]   Variation of heat release rate with forced longitudinal ventilation for vehicle fires in tunnels [J].
Carvel, RO ;
Beard, AN ;
Jowitt, PW ;
Drysdale, DD .
FIRE SAFETY JOURNAL, 2001, 36 (06) :569-596
[4]   Simulation of ventilation and fire in the underground facilities [J].
Cheng, LH ;
Ueng, TH ;
Liu, CW .
FIRE SAFETY JOURNAL, 2001, 36 (06) :597-619
[5]   Fires in tunnels [J].
Grant, GB ;
Jagger, SF ;
Lea, CJ .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1998, 356 (1748) :2873-2906
[6]  
Hong W, 2004, 6 AS OC S FIR SCI TE, P28
[7]   Studies on buoyancy-driven back-layering flow in tunnel fires [J].
Hu, L. H. ;
Huo, R. ;
Chow, W. K. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 32 (08) :1468-1483
[8]   Modeling fire-induced smoke spread and carbon monoxide transportation in a long channel: Fire Dynamics Simulator comparisons with measured data [J].
Hu, L. H. ;
Fong, N. K. ;
Yang, L. Z. ;
Chow, W. K. ;
Li, Y. Z. ;
Huo, R. .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 140 (1-2) :293-298
[9]   Experimental and numerical studies on longitudinal smoke temperature distribution upstream and downstream from the fire in a road tunnel [J].
Hu, L. H. ;
Huo, R. ;
Wang, H. B. ;
Yang, R. X. .
JOURNAL OF FIRE SCIENCES, 2007, 25 (01) :23-43
[10]   On the maximum smoke temperature under the ceiling in tunnel fires [J].
Hu, L. H. ;
Huo, R. ;
Peng, W. ;
Chow, W. K. ;
Yang, R. X. .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2006, 21 (06) :650-655