Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly(methyl methacrylate) lenses

被引:92
作者
Nishi, O
Nishi, K
Akura, J
机构
[1] Nishi Eye Hosp, Higashinari Ku, Osaka 5370025, Japan
[2] Kushimoto Rehabil Ctr, Wakayama, Japan
关键词
D O I
10.1016/S0886-3350(01)01094-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate how and how fast a capsular bend is created clinically at the optic edge of an intraocular lens (IOL) after cataract surgery. Setting. Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. Methods. Capsular bend formation was observed by slitlamp after maximum pupil dilation in 45 eyes of 45 patients with senile cataract. Fifteen eyes each received an AcrySof(R) MA60BM acrylic (Alcon), PhacoFlex II(R) SI-40NB silicone (Allergan), or UV26T poly(methyl methacrylate) (PMMA) (Menicon) IOL. Patients were evaluated prospectively at 1 day and 1, 2, and 4 weeks and retrospectively (15 eyes per IOL) 1 year after cataract surgery. A capsular bend index was developed to document and categorize the capsular bend formation process at the IOL optic edge. Results. The anterior and posterior capsules adhered, with the latter attracted to the former. The adhesion always progressed from the periphery to the optic edge so that the posterior capsule eventually wrapped around the posterior optic edge, although not fully circumferentially in ail cases. The process took place in 4 stages. Capsular bend formation was complete 1 month after surgery with the foldable 1OLs (AcrySof, PhacoFlex 11) but was significantly delayed with the PMMA IOL. After 1 year, the capsular wrapping was firm and fully circumferential at the optic edge with all IOL types in all cases. Conclusions: Capsular bend formation progressed in the same fashion but at significantly different speeds among the 1OLs, suggesting that the process depends on IOL material and design. Fast, early capsular bend formation may be 1 reason AcrySof and PhacoFlex II IOLs prevent PCO statistically better than PMMA IOLs. The results indicate that PCO is prevented by the sharp capsular bend created by sharp optic edges and by quick bend formation. (C) 2002 ASCRS and ESCRS.
引用
收藏
页码:431 / 437
页数:7
相关论文
共 15 条
[1]  
BIRK D, 1994, MOL BIOL CELL, P969
[2]   Silicone IOL biocompatibility - Not all silicone is the same [J].
Chang, DF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08) :1102-1102
[3]   Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation [J].
Hayashi, H ;
Hayashi, K ;
Nakao, F ;
Hayashi, F .
ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (12) :1579-1582
[4]   The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery [J].
Hollick, EJ ;
Spalton, DJ ;
Ursell, PG ;
Pande, MV ;
Barman, SA ;
Boyce, JF ;
Tilling, K .
OPHTHALMOLOGY, 1999, 106 (01) :49-54
[5]   Adhesiveness of AcrySof to a collagen film [J].
Nagata, T ;
Minakata, A ;
Watanabe, I .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (03) :367-370
[6]   Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges [J].
Nishi, O ;
Nishi, K ;
Wickström, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (10) :1543-1549
[7]  
Nishi O, 1998, OPHTHALMIC SURG LAS, V29, P587
[8]   Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule [J].
Nishi, O ;
Nishi, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (04) :521-526
[9]  
Nishi O, 1997, INVEST OPHTH VIS SCI, V38, P579
[10]   Effect of round-edged acrylic intraocular lenses on preventing posterior capsule opacification [J].
Nishi, O ;
Nishi, K ;
Akura, J ;
Nagata, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04) :608-613