Specification and initial evaluation of a multiple application teleradiology system

被引:15
作者
OHare, NJ
Wallis, F
Kennedy, JMT
Hickey, E
McDermott, GJ
Dowling, A
Murphy, J
Malone, JF
机构
[1] ST JAMES HOSP,DEPT DIAGNOST IMAGING,DUBLIN 8,IRELAND
[2] CAPTEC LTD,MALAHIDE,DUBLIN,IRELAND
[3] TALLAGHT RTC,DEPT PHYS,DUBLIN 24,IRELAND
关键词
D O I
10.1259/0007-1285-69-824-735
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The digitization and transmission of medical images is becoming increasingly more important and available. The selection of appropriate clinical applications for teleradiology systems is an important factor in determining the success of such ventures. In this paper, the selection of such applications and the evaluation of the teleradiology system is described. The system (LIAISON(TM), CAPTEC Ltd, Malahide, Ireland) is PC based and is capable of digitization and transmission of three categories of medical images: (1) plain film radiographs; (2) CT film data and (3) video sequences such as ultrasound scans. A comprehensive technical evaluation was carried out on the acquisition and display station in which various parameters such as spatial resolution, signal-to-noise ratio (SNR), and distortion were investigated. Results showed that the system performed well within specifications. An exploratory clinical evaluation was performed using a case mix of subtle fractures, chests and dislocations, and CT scans. Here the system performed well with a diagnostic accuracy of 95% for the digital image compared with the analogue image.
引用
收藏
页码:735 / 742
页数:8
相关论文
共 30 条
  • [1] RECEIVER OPERATING CHARACTERISTIC ANALYSIS OF FRACTURE AND PNEUMONIA DETECTION - COMPARISON OF LASER-DIGITIZED WORKSTATION IMAGES AND CONVENTIONAL ANALOG RADIOGRAPHS
    ACKERMAN, SJ
    GITLIN, JN
    GAYLER, RW
    FLAGLE, CD
    BRYAN, RN
    [J]. RADIOLOGY, 1993, 186 (01) : 263 - 268
  • [2] ALLISON D, 1994, 18 INT C RAD SING 23
  • [3] BUSHBERG JT, 1994, ESSENTIAL PHYSICS ME, P367
  • [4] DIGITAL MAMMOGRAPHY - ROC STUDIES OF THE EFFECTS OF PIXEL SIZE AND UNSHARP-MASK FILTERING ON THE DETECTION OF SUBTLE MICROCALCIFICATIONS
    CHAN, HP
    VYBORNY, CJ
    MACMAHON, H
    METZ, CE
    DOI, K
    SICKLES, EA
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (07) : 581 - 589
  • [5] CURRY TS, 1990, CHRISTENSENS PHYSICS, P149
  • [6] DAWOOD RM, 1994, BRIT J RADIOL, V67, P1
  • [7] Feigenbaum H, 1994, J Am Soc Echocardiogr, V7, P105
  • [8] FISHER P, 1990, SPIE MED IMAGING 4, V1234, P553
  • [9] THE EFFECT OF VARYING SPATIAL-RESOLUTION ON THE DETECTABILITY OF DIFFUSE PULMONARY NODULES - ASSESSMENT WITH DIGITIZED CONVENTIONAL RADIOGRAPHS
    FOLEY, WD
    WILSON, CR
    KEYES, GS
    DIBIANCA, FA
    SCANLON, GT
    SCHLEUTER, D
    LAWSON, TL
    [J]. RADIOLOGY, 1981, 141 (01) : 25 - 31
  • [10] TELERADIOLOGY FOR A FAMILY-PRACTICE CENTER
    FRANKEN, EA
    DRISCOLL, CE
    BERBAUM, KS
    SMITH, WL
    SATO, Y
    STEINKRAUS, LW
    KAO, SCS
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1989, 261 (20): : 3014 - 3015