Automatic detection of lytic and blastic thoracolumbar spine metastases on computed tomography

被引:44
作者
Hammon, Matthias [1 ]
Dankerl, Peter [1 ]
Tsymbal, Alexey [2 ]
Wels, Michael [2 ]
Kelm, Michael [2 ]
May, Matthias [1 ]
Suehling, Michael [2 ]
Uder, Michael [1 ]
Cavallaro, Alexander [1 ]
机构
[1] Univ Hosp Erlangen, Dept Radiol, D-91054 Erlangen, Germany
[2] Siemens AG, Corp Technol Div, D-91058 Erlangen, Germany
关键词
Computer-aided detection (CADe); Bone metastases; Computed tomography (CT); Spine; Clinical decision support; AIDED DETECTION; BONE; CT; CANCER; MRI; PERFORMANCE; DIAGNOSIS; PET; CAD;
D O I
10.1007/s00330-013-2774-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate a computer-aided detection (CADe) system for lytic and blastic spinal metastases on computed tomography (CT). We retrospectively evaluated the CADe system on 20 consecutive patients with 42 lytic and on 30 consecutive patients with 172 blastic metastases. The CADe system was trained using CT images of 114 subjects with 102 lytic and 308 blastic spinal metastases. Lesions were annotated by experienced radiologists. Detected benign lesions were considered false-positive findings. Detector sensitivity and the number of false-positive findings were calculated as the criteria for detector performance, and free-response receiver operating characteristic (FROC) analysis was conducted. Detailed analysis of false-positive and false-negative findings was performed. Algorithm runtime is 3 +/- 0.5 min per patient. The system achieves a sensitivity of 83 % at 3.5 false positives per patient on average for blastic metastases and a sensitivity of 88 % at 3.7 false positives for lytic metastases. False positives appeared predominantly in the area of degenerative changes in the case of the blastic metastasis detector and in osteoporotic areas in the case of the lytic metastasis detector. The CADe system reliably detects thoracolumbar spine metastases in real time. An additional study is planned to evaluate how the bone lesion CADe system improves radiologists' accuracy and efficiency in a clinical setting. aEuro cent Computer-aided detection (CADe) of bone metastases has been developed for spinal CT. aEuro cent The CADe system exhibits high sensitivity with a tolerable false-positive rate. aEuro cent Analysis of false-positive detection may further improve the system. aEuro cent CADe may reduce the number of missed spinal metastases at CT interpretation.
引用
收藏
页码:1862 / 1870
页数:9
相关论文
共 35 条
[1]   DO METASTASES IN VERTEBRAE BEGIN IN THE BODY OR THE PEDICLES - IMAGING STUDY IN 45 PATIENTS [J].
ALGRA, PR ;
HEIMANS, JJ ;
VALK, J ;
NAUTA, JJ ;
LACHNIET, M ;
VANKOOTEN, B .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (06) :1275-1279
[2]   Optimizing Analysis, Visualization, and Navigation of Large Image Data Sets: One 5000-Section CT Scan Can Ruin Your Whole Day [J].
Andriole, Katherine P. ;
Wolfe, Jeremy M. ;
Khorasani, Ramin ;
Treves, S. Ted ;
Getty, David J. ;
Jacobson, Francine L. ;
Steigner, Michael L. ;
Pan, John J. ;
Sitek, Arkadiusz ;
Seltzer, Steven E. .
RADIOLOGY, 2011, 259 (02) :346-362
[3]   Addressing the coming radiology crisis -: The society for computer applications in radiology transforming the radiological interpretation process (TRIP™) initiative [J].
Andriole, KP ;
Morin, RL ;
Arenson, RL ;
Carrino, JA ;
Erickson, BJ ;
Horii, SC ;
Piraino, DW ;
Reiner, BI ;
Seibert, JA ;
Siegel, E .
JOURNAL OF DIGITAL IMAGING, 2004, 17 (04) :235-243
[4]   Multiple myeloma: Clinical review and diagnostic imaging [J].
Angtuaco, EJC ;
Fassas, ABT ;
Walker, R ;
Sethi, R ;
Barlogie, B .
RADIOLOGY, 2004, 231 (01) :11-23
[5]   FDG PET of primary benign and malignant bone tumors: Standardized uptake value in 52 lesions [J].
Aoki, J ;
Watanabe, H ;
Shinozaki, T ;
Takagishi, K ;
Ishijima, H ;
Oya, N ;
Sato, N ;
Inoue, T ;
Endo, K .
RADIOLOGY, 2001, 219 (03) :774-777
[6]   Automated computer-aided stenosis detection at coronary CT angiography: initial experience [J].
Arnoldi, Elisabeth ;
Gebregziabher, Mulugeta ;
Schoepf, U. Joseph ;
Goldenberg, Roman ;
Ramos-Duran, Luis ;
Zwerner, Peter L. ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Costello, Philip ;
Thilo, Christian .
EUROPEAN RADIOLOGY, 2010, 20 (05) :1160-1167
[7]  
Barbu A, 2010, LECT NOTES COMPUT SC, V6361, P28
[8]   Computer-aided detection of pulmonary embolism at CT pulmonary angiography: can it improve performance of inexperienced readers? [J].
Blackmon, Kevin N. ;
Florin, Charles ;
Bogoni, Luca ;
McCain, Joshua W. ;
Koonce, James D. ;
Lee, Heon ;
Bastarrika, Gorka ;
Thilo, Christian ;
Costello, Philip ;
Salganicoff, Marcos ;
Schoepf, U. Joseph .
EUROPEAN RADIOLOGY, 2011, 21 (06) :1214-1223
[9]   Random forests [J].
Breiman, L .
MACHINE LEARNING, 2001, 45 (01) :5-32
[10]   Diagnostic Imaging and Image-Guided Therapy of Skeletal Metastases [J].
Choi, Junsung ;
Raghavan, Meera .
CANCER CONTROL, 2012, 19 (02) :102-112