Effect of liner design, pulsator setting, and vacuum level on bovine teat tissue changes and milking characteristics as measured by ultrasonography

被引:41
作者
Gleeson, DE [1 ]
O'Callaghan, EJ
Rath, MV
机构
[1] TEAGASC, Moorepk Res Ctr, Fermoy, Cork, Ireland
[2] Univ Coll Dublin, Fac Agr, Dublin 4, Ireland
关键词
cattle; machine milking; teat tissue; pulsation; milk liner; ultrasonography;
D O I
10.1186/2046-0481-57-5-289
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Friesian-type dairy cows were milked with different machine settings to determine the effect of these settings on teat tissue reaction and on milking characteristics. Three teat-cup Liner designs were used with varying upper barrel. dimensions (wide-bore WB= 31.6mm; narrow-bore NB= 21.0mm; narrow-bore NB1=25.0mm). These liners were tested with alternate and simultaneous pulsation patterns, pulsator ratios (60:40 and 67:33) and three system vacuum Levels (40, 44 and 50kPa). Teat tissue was measured using ultrasonography, before milking and directly after milking. The measurements recorded were teat canal Length (TCL), teat diameter (TD), cistern diameter (0) and teat watt thickness (TWT). Teat tissue changes were similar with a system vacuum level of either 50kPa (mid-Level.) or 40kPa (low-level). Widening the Liner upper barrel bore dimension from 21.0mm (P<0.01) or 25.0mm (P<0.001) to 31.6mm increased the magnitude of changes in TD and TWT after machine milking. Milk yield per cow was significantly (P<0.05) higher and cluster-on time was reduced (P<0.01) with the WB cluster as compared to the NB1 cluster. Minimum changes in teat tissue parameters were achieved with system vacuum Level. of 40kPa and 50kPa using NB and WB clusters, respectively. Similar changes in teat tissue and milk yield per cow were observed with alternate and simultaneous pulsation patterns. Widening pulsator ratio from 60:40 to 67:33 did not have negative effects on changes in teat tissue and had a positive effect on milk yield and milking time. Milk Liner design had a bigger effect on teat tissue changes and milking characteristics than pulsation settings.
引用
收藏
页码:289 / 296
页数:8
相关论文
共 21 条
  • [1] Banting A., 1998, Cattle Practice, V6, P121
  • [2] BRANDSMAN S, 1968, P S MACH MILK U READ, P1
  • [3] CRAIG TV, 1991, J DAIRY SCI, V74, P1243
  • [4] Gleeson DE, 2002, IRISH VET J, V55, P628
  • [5] GLEESON DE, 2001, P IRISH GRASSLAND AS, V27, P65
  • [6] GLEESON DE, 1999, P ANN M NAT MAST COU, V38, P209
  • [7] MEASUREMENT OF MACHINE-INDUCED CHANGES IN THICKNESS OF THE BOVINE TEAT
    HAMANN, J
    MEIN, GA
    [J]. JOURNAL OF DAIRY RESEARCH, 1990, 57 (04) : 495 - 505
  • [8] HAMANN J, 1988, MILCHWISSENSCHAFT, V43, P651
  • [9] Recommended method for measuring changes in thickness of the bovine teat with spring-loaded calipers
    Hamann, J
    Mein, GA
    Nipp, B
    [J]. JOURNAL OF DAIRY RESEARCH, 1996, 63 (02) : 309 - 313
  • [10] TEAT TISSUE-REACTIONS TO MILKING - EFFECTS OF VACUUM LEVEL
    HAMANN, J
    MEIN, GA
    WETZEL, S
    [J]. JOURNAL OF DAIRY SCIENCE, 1993, 76 (04) : 1040 - 1046