Simultaneous quantification of doxorubicin, lorazepam, metoclopramide, ondansetron, and ranitidine in mixtures by liquid chromatography-tandem mass spectrometry

被引:25
作者
Abdel-Hamid, ME [1 ]
Sharma, D [1 ]
机构
[1] Kuwait Univ, Fac Pharm, Dept Pharmaceut Chem, Safat, Kuwait
关键词
doxorubicin; lorazepam; metoclopramide; Ondansetron; ranitidine; LC-MS/MS;
D O I
10.1081/JLC-120028254
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and rapid LC-MS/MS method for simultaneous quantification of a mixture of the antineoplastic agent doxorubicin (Dox) and selected emesis suppressants, namely, lorazepam (Lor), metoclopramide (Met), ondansetron (Ond), and ranitidine (Ran), was developed. 4-Phenyl-4-aminobutanoic acid was used as the internal standard (I.S.). The analytes were analyzed on an Xterra(TM) MS, C-18, 2.5 mum (2.1 mm x 30 mm) column using 70% aqueous methanol containing 0.1% formic acid. The investigated compounds were detected by tandem mass spectrometry (MS/MS) using a positive electrospray ionization mode. Multiple reaction monitoring transitions at m/z 544>361, 323>277, 301>228, 294>169, 315>176 and 180>163 (I.S.) were selected for simultaneous quantitation of Dox, Lot, Met, Ond, and Ran by an I.S. method. Calibration curves were constructed over the concentration ranges 10-200 ng mL(-1) (Dox, Lor), 8-80 ng mL(-1) (Ond), Met and Ran (1-10 ng mL(-1)). The coefficient of determination ranged from 0.9953 to 0.9998 with a limit of detection of similar to1 ng mL(-1) for all analytes. The overall percentage standard deviation and percentage deviation were <10% indicating good precision and accuracy. The developed LC-MS/MS method quantitatively recovered doxorubicin and the co-admixed compounds in the range 98.1%-103.5%. The data suggest the utility of the developed LC-MS/MS procedure for simultaneous routine analysis of mixtures of Dox and the emesis suppressants, Lor, Met, Ond, and Ran in I.V. infusions in clinics.
引用
收藏
页码:641 / 660
页数:20
相关论文
共 13 条
[1]   LC-MS/MS determination of Synercid® injections [J].
Abdel-Hamid, ME ;
Phillips, OA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (06) :1167-1174
[2]   LC-MS/MS determination of carbamazepine, pindolol, and theophylline in human serum [J].
Abdel-Hamid, ME ;
Phillips, OA .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (12) :1937-1957
[3]  
[Anonymous], 1997, ELECTROSPRAY IONIZAT
[4]   HPLC DETERMINATION OF A VINCRISTINE, DOXORUBICIN, AND ONDANSETRON MIXTURE IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION [J].
KING, DT ;
VENKATESHWARAN, TG ;
STEWART, JT .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (06) :1399-1411
[5]   Simultaneous determination of four anthracyclines and three metabolites in human serum by liquid chromatography-electrospray mass spectrometry [J].
Lachâtre, F ;
Marquet, P ;
Ragot, S ;
Gaulier, JM ;
Cardot, P ;
Dupuy, JL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 738 (02) :281-291
[6]  
NIESSEN WMA, 1998, LIQUID CHROMATOGRAPH, P405
[7]  
Pérez-Ruiz T, 2001, ELECTROPHORESIS, V22, P134, DOI 10.1002/1522-2683(200101)22:1<134::AID-ELPS134>3.3.CO
[8]  
2-O
[9]   HPLC determinations of ondansetron with selected medications in 0.9% sodium chloride injection USP [J].
Venkateshwaran, TG ;
Stewart, JT ;
King, DT .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (20) :3355-3367
[10]   HPLC DETERMINATION OF ONDANSETRON-ATROPINE AND ONDANSETRON-GLYCOPYRROLATE MIXTURES IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION [J].
VENKATESHWARAN, TG ;
KING, DT ;
STEWART, JT .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (13) :2647-2659